5. MAINTENANCE
WARNING! Ensure the pressure washer is switched off and unplugged from the electrical power supply and turned off at the
water supply tap before proceeding.
p
5.1.
Take the nozzle cleaning tool, detach the lance from the gun and remove any dirt from nozzle, then rinse.
5.2.
Check washer, gun, lance, hose, connections and cables for damage regularly. Repair or replace any damaged items before next use.
DO NOT open the casing, use authorised agent to service the washer.
5.3
If storing the washer for a long period during winter ensure that the temperature of the storage area does not drop below freezing.
Alternatively operate the washer with a non-corrosive, non-toxic anti-freeze before storage.
5.4
Check the oil level on a regular basis by removing the dipstick and observing the oil level in relation to the rib on the
dipstick. Top up if required with multigrade oil SAE 20/30.
5.5
Periodically flush out the detergent system with clean water to eliminate build up of detergent deposits.
5.6.
Keep the washer clean at all times.
6.
TROUBLESHOOTING GUIDE
SYMPTOM
Pump does not reach required pressure
Pressure drops during use
Pump noisy
Presence of water in oil
Oil leaks
Motor does not start when switched on
Motor hums but does not start when
switched on
Water dripping from pump
The motor stops
Fluctuating pressure
Declaration of Conformity We, the sole importer into the UK of Sealey Power Products, declare that the products listed below are in
conformity with the following standards and directives.
Pressure Washers
PC1750, PC1850, PC2000
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
98/37/EEC Machinery Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No responsibility is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
REASON
Nozzle incorrect or worn
Air being sucked into system
Water pressure low
Worn piston packing
Valves dirty, worn or stuck
Valves dirty or worn
Nozzle worn or blocked
Unloader valve packing worn
Worn piston packing
Water too hot
Pump sucking air
Valves dirty or worn
Worn piston packing
Water too hot
High humidity in air
Piston packing and oil seal worn
Oil seals worn
Plug is not connected
No electrical power
Unsuitable mains voltage
Motor / Pump is stuck
Pump is frozen
Incorrect extension cable
Piston packings worn
Piston guide O-ring worn
Tripped thermal overload due to overheating
Valves worn, dirty or stuck
Pump sucking air
Worn piston packing
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power
Sole U.K. Distributor,
Sealey Group,
Bury St. Edmunds, Suffolk.
REMEDY
Replace the nozzle
Check that hoses and fittings are air tight
Check that hoses / fittings are watertight and tap is fully open
Contact Authorised Service Agent
Contact Authorised Service Agent
Contact Authorised Service Agent
Clean out or replace the nozzle
Contact Authorised Service Agent
Contact Authorised Service Agent
Reduce temperature
Check that hoses and fittings are tight
Contact Authorised Service Agent
Contact Authorised Service Agent
Reduce temperature
Check and replace oil twice as often
Contact Authorised Service Agent
Contact Authorised Service Agent
Insert plug and/or check plug connections
Check that mains power is active
Check for adequate power supply and cable condition
If jammed return to Sealey dealer
Leave unit to thaw naturally. ( The washer should be protected from
freezing conditions as extensive pump damage could result. See
Maintenance. )
Use a suitable extension cable. See Section 1 ( Electrical safety )
Contact Authorised Service Agent
Contact Authorised Service Agent
Check that mains voltage matches the specifications
Switch off the motor and let the machine cool for 5 minutes
Contact Authorised Service Agent
Check that hoses and fittings are airtight
Contact Authorised Service Agent
The construction files for these product are held by the Manufacturer and
may be inspected, by a national authority, upon request to Jack Sealey Ltd.
01284 757500
01284 703534