Mitsubishi Electric ecodan EHPT20Q-VM2EA Installation Manual page 17

Cylinder unit
Hide thumbs Also See for ecodan EHPT20Q-VM2EA:
Table of Contents

Advertisement

5
System Set Up
<Main Controller Menu Tree>
Initial
Main screen
F1
Information
F4
Option
F1
Forced DHW
F2
DHW
F3
Heating
Menu
F4
Short Press
Main
menu
Main
F2 (
menu
DHW
Long Press
Hot Water (DHW)
<See
section>
F1
(Zone1)
F3
(PREVIEW)
Heating
<See
section>
F4
(
EDIT)
F4
Schedule2 period setting screen1
(
EDIT)
Schedule2 period
preview screen
Schedule timer
<See
section>
Schedule1/2 select
DHW
Heating
Holiday mode
F3
Holiday menu
<See
section>
(
EDIT)
Date/Time
Language
Summer time
Temp. display
Contact number
Initial settings
<See
section>
Time display
°C/°F
Room sensor settings
<Continued to next page.>
32
Unrestricted access
Installer only
Long press
ON ( )/OFF
ON ( )/Prohibited ( )/Timer ( )
ON ( )/Prohibited ( )/Timer ( )
Consumed electrical energy
Delivered energy
DHW supply max. temp.
DHW supply max. temp. drop
EDIT)
DHW max. operation time
DHW mode restriction
DHW storage volume
Room temp.(
) / Flow temp.(
) / Compensation curve(
)
Compensation curve preview
Compensation curve edit
F2
F3
Curve parameters
Zone1
F4
Adjustment
F2
F3
Term setting
F4
F4
Schedule timer preview
Day
Zone1
select
F1
Zone1/2 select
F4
Schedule timer preview
Day
Heating
Zone2
Schedule1
select
F4
Schedule timer preview
Day
select
DHW
Schedule timer preview
F4
Day
Zone1
F1
select
Zone1/2 select
F4
Schedule timer preview
Heating
Day
Zone2
Schedule2
select
F4
Schedule timer preview
Day
select
DHW
Active/Non active
Active/Non active
Zone1
Heating room temp.
F2
Zone1/2 select
F1
Heating fl ow temp.
Zone2
Heating room temp.
yyyy/mm/dd/hh:mm
English/Français/Deutsch/Svenska/Español/Italiano/Dansk/NL/Norsk
OFF/ON
OFF/Room/Tank/Room&Tank
hh:mm/hh:mm AM/AM hh:mm
°C/°F
Sensor setting
TH1/Main RC/
Room RC zone select
Room RC1-8/
"Time/Zone"
Zone1
Time setting
Select Time/Zone
F1
F2
Sensor setting
Zone1/2 select
Sensor setting
Sensor setting
TH1/Main controller/
Room RC1-8/
"Time/Zone"
Zone2
Time setting
Select Time/Zone
Sensor setting
5
System Set Up
<Main Controller Menu Tree>
Initial
Main screen
Menu
Short Press
Main
menu
Main
menu
Long Press
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
save
<Continued from the previous page.>
Manual operation
Function settings
Service
Thermistor adjustment
Password protected
<See
section>
Economy settings for pump
Auxiliary settings
Electric heater (Heating)
Heat source setting
Standard (Heat pump & electric heater)/Heater (Electric heater only)
Pump speed
Operation settings
Heating
Flow temp.range
operation
Room temp.control
H/P thermo diff.adjust
Flow rate setting(Heating)
Freeze stat function
Electric heater
capacity
Energy monitor
Water pump input
settings
Delivered energy adjustment
Electric energy meter
Heat meter
Running information
Thermistor reading
Summary of settings
Error history
Password protection
Main controller
Manual reset
FTC
SD → Main RC
SD card
Main RC → SD
Unrestricted access
Installer only
Long press
ON/OFF
Delay
ON/OFF
Delay
Min.temp.
Max.temp.
Mode
Interval
ON/OFF
Lower limit
Upper limit
Mode
Flow rate
Flow t.
Outdoor ambient temp.
Booster heater 1 capacity
Pump 1
Yes/No
Yes/No
F1
F2
F3
Select download data
F1
F2
F3
Select upload data
33