Available languages

General product
maintenance
Do a complete serv-
icing and cleaning of
the product.
To clean the product
Always clean all the equipment after use. Use a
vacuum cleaner.
Do not use a high-pressure washer to clean the
product.
Keep the air openings clean and clear to make
sure that the product always has sufficiently cool
temperature.
To clean the compressor filters
CAUTION:
washer or water to clean the compressor
filters. Do not hit the filters with force to
clean them. Do not use pressurized air to
clean the compressor filters.
1. Remove the 2 caps and the 2 compressor filters (A).
B
2. Clean the 2 compressor filters with a small dust
extractor (B).
3. Install the 2 compressor filters and close the 2 caps.
If you cannot fully clean the compressor filters or if they
are damaged, it is necessary to replace them.
To clean the filter in the water
separator
CAUTION:
washer to clean the filter. Do not hit the filter
with force to clean it.
2061 - 002 - 19.04.2023
Weekly
Daily
Do not use a high-pressure
A
Do not use a high-pressure
After 200 h of operat-
12 h after
ing time
servicing
1. Remove the filter in the water separator. Refer to
replace the filter in the water separator on page 17 .
2. Clean the filter with warm water.
3. Dry the filter with pressurized air.
4. Install the filter. Refer to
water separator on page 17 .
To replace the filter in the water separator
1. Stop the product. Refer to
page 11 .
2. Remove the bowl of the water separator (A).
3. Replace the filter of the water separator (B).
4. Install the bowl of the water separator (A).
To clean the primary filters
WARNING:
intake when the pulse cleaning cycle runs. If
the air intake is not closed, dust can come in
to the air. The dust particles are dangerous
to your health.
1. Start the product. Refer to
page 10 .
2. Stop the fan. Refer to
11 .
3. Keep the air compressor on for 30 minutes while
the product is not in operation. Pressurized air goes
through the primary filters and cleans them.
Each 3
Yearly
months
To replace the filter in the
To stop the product on
B
A
Always close off the air
To start the product on
To stop the product on page
O
To
17