Siemens RUGGEDCOM M2100F Installation Manual

Hide thumbs Also See for RUGGEDCOM M2100F:

Advertisement

Quick Links

RUGGEDCOM M2100F
Installation Guide
07/2018
RC1342-EN-02
Preface
Introduction
Installing Device
Device Management
Communication Ports
Technical Specifications
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM M2100F

  • Page 1 Preface Introduction Installing Device RUGGEDCOM M2100F Device Management Communication Ports Technical Specifications Installation Guide Certification 07/2018 RC1342-EN-02...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM M2100F Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario https://www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM M2100F Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM M2100F   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 6   RUGGEDCOM M2100F Table of Contents Installation Guide Chapter 4 Communication Ports ..................4.1  Copper Ethernet Ports ......................... 22 4.2  Fiber Optic Ethernet Ports ......................23 Chapter 5 Technical Specifications .................. 5.1  Power Supply Specifications ......................25 5.2  Failsafe Relay Specifications ......................26 5.3  Supported Networking Standards ....................26 5.4  Copper Ethernet Port Specifications ....................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM M2100F. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9: Customer Support

    RUGGEDCOM M2100F   Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
  • Page 10   RUGGEDCOM M2100F Preface Installation Guide Customer Support...
  • Page 11: Introduction

    M2100F highly versatile for any application and can support multiple fiber connectors (ST, MTRJ, LC, SC) without loss of port density. The RUGGEDCOM M2100F is packaged in a rugged galvanized steel enclosure with industrial grade DIN, panel, or 48 cm (19 in) rack-mount mounting options.
  • Page 12: Description

    Section 1.2 Description The RUGGEDCOM M2100F features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 13: Required Tools And Materials

    Section 3.1, “Connecting to the Device”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM M2100F: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. CAT-5 Ethernet cables For connecting the device to the network.
  • Page 14: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15: Supported Fiber Optic Cables

    Security seals provide evidence of unauthorized tampering or removal of components. IMPORTANT! Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. Supported Fiber Optic Cables...
  • Page 16 Chapter 1 RUGGEDCOM M2100F Introduction Installation Guide There are three ways to determine if a security seal has been tampered with: • The seal is cut or torn • A pattern is left on the device when the top layer of the seal is removed •...
  • Page 17: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 18: Unpacking The Device

    Section 2.3 Mounting the Device The RUGGEDCOM M2100F is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack or directly on a panel. IMPORTANT! Heat generated by the device is channeled outwards from the enclosure.
  • Page 19: Mounting The Device To A Rack

    Section 2.3.1 Mounting the Device to a Rack The RUGGEDCOM M2100F can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 20: Mounting The Device To A Panel

    Section 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM M2100F can be equipped with panel adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws. To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes.
  • Page 21: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROS-F. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS-F User Guide for the RUGGEDCOM M2100F. The following shows the proper relay connections.
  • Page 22: Connecting Power

    The RUGGEDCOM M2100F supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM M2100F can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies. The screw-type terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 23: Connecting Ac Or Dc Power

    RUGGEDCOM M2100F Chapter 2 Installation Guide Installing Device Section 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the field, remove the metal jumper.
  • Page 24: Wiring Examples

    Chapter 2 RUGGEDCOM M2100F Installing Device Installation Guide Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to the chassis ground terminal. The surge ground terminals are used as the ground conductor for all surge and transient suppression circuitry internal to the unit.
  • Page 25 RUGGEDCOM M2100F Chapter 2 Installation Guide Installing Device Figure 7: Single AC Power Supply Figure 8: Single DC Power Supply Wiring Examples...
  • Page 26 Chapter 2 RUGGEDCOM M2100F Installing Device Installation Guide Figure 9: Dual AC Power Supply Figure 10: Dual DC Power Supply Wiring Examples...
  • Page 27 RUGGEDCOM M2100F Chapter 2 Installation Guide Installing Device Figure 11: Dual AC/DC Power Supply Wiring Examples...
  • Page 28 Chapter 2 RUGGEDCOM M2100F Installing Device Installation Guide Wiring Examples...
  • Page 29: Device Management

    Connecting to the Device The following describes the various methods for accessing the ROS-F console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS-F User Guide for the RUGGEDCOM M2100F. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and ROS-F interfaces.
  • Page 30: Configuring The Device

    Chapter 3 RUGGEDCOM M2100F Device Management Installation Guide Name Description Comment RJ45 Male Female Read to Send Ring Indicator The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected.
  • Page 31: Communication Ports

    Chapter 4 Installation Guide Communication Ports Communication Ports The RUGGEDCOM M2100F can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 13: Module Assignment Each type of module has a specific location in the RUGGEDCOM M2100F chassis: •...
  • Page 32: Copper Ethernet Ports

    Section 4.1 Copper Ethernet Ports The RUGGEDCOM M2100F supports several 10/100Base-TX and 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with Micro-D male connectors. The Micro-D connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 33: Fiber Optic Ethernet Ports

    RUGGEDCOM M2100F Chapter 4 Installation Guide Communication Ports Specifications For specifications on the available copper Ethernet ports, refer to Section 5.4, “Copper Ethernet Port Specifications”. Section 4.2 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Registered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors.
  • Page 34 Chapter 4 RUGGEDCOM M2100F Communication Ports Installation Guide Fiber Optic Ethernet Ports...
  • Page 35: Technical Specifications

    Section 5.8, “Dimension Drawings” Section 5.1 Power Supply Specifications The RUGGEDCOM M2100F can be equipped with the following power supplies: CAUTION! Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power input is above or below the specified input range.
  • Page 36: Failsafe Relay Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 37: Fiber Optic Ethernet Port Specifications

    -11.2 14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications...
  • Page 38: Operating Environment

    Technical Specifications Installation Guide Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Gigabit Ethernet (1 Gbps) Optical Specifications NOTE These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20 to 85 °C (-4 to...
  • Page 39: Dimension Drawings

    RUGGEDCOM M2100F Chapter 5 Installation Guide Technical Specifications Section 5.8 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. NOTE Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stated. 438.15 Figure 20: Overall Dimensions Dimension Drawings...
  • Page 40 Chapter 5 RUGGEDCOM M2100F Technical Specifications Installation Guide 32.77 21.08 11.68 479.29 478.79 4.57 Figure 21: Rack Mount Dimensions Dimension Drawings...
  • Page 41 RUGGEDCOM M2100F Chapter 5 Installation Guide Technical Specifications 467.4 275.6 482.6 Figure 22: Panel Mount Dimensions Dimension Drawings...
  • Page 42 Chapter 5 RUGGEDCOM M2100F Technical Specifications Installation Guide Dimension Drawings...
  • Page 43: Certification

    RUGGEDCOM M2100F Chapter 6 Installation Guide Certification Certification The RUGGEDCOM M2100F device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 44: European Union (Eu)

    Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 45: Ised

    Installation Guide Certification Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 This device was designed and manufactured using a certified ISO (International Organization for Standardization) quality program that adheres to the following standard: •...
  • Page 46: Emc And Environmental Type Tests

    Certification Installation Guide Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM M2100F has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 NOTE • In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise, all Class 1 requirements are met for copper ports.
  • Page 47 EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM M2100F meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 48 Chapter 6 RUGGEDCOM M2100F Certification Installation Guide Description Test Levels 1 kV differential mode @ 1 MHz AC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz HV Impulse Signal Ports 5 kV (Fail-Safe Relay Output) DC Power Ports...