Second Connection Point Of Equipment Grounding Conductor - Bosch REXROTH IndraDrive Mi KSM01 Operating Instructions Manual

Distributed servo drive
Table of Contents

Advertisement

DOK-INDRV*-KSM01******-IT01-EN-P
Rexroth IndraDrive Mi Distributed Servo Drive KSM01
Selection of Hybrid Cables
Identification of Hybrid Cables
Terminal Connector
5.3.5

Second Connection Point of Equipment Grounding Conductor

Fig.5-8:
Example of Drive System With Hybrid Cable
Each string of distributed servo drives KSM must be terminated with the ter‐
minal connector RHS0004.
All hybrid cables are suited for use in flexible cable tracks. In the example,
the cable RKH0700 is used in a flexible cable track. To quickly replace the
flexible cable track cable for servicing, the cable in the example used in the
flexible cable track has been equipped with connectors at the inputs. Observe
the maximum allowed length of the hybrid cable in the flexible cable track.
Hybrid cables are marked according to the following example.
RKH0100/030,5
The cable designation is made up of:
Cable number ⇒ e.g. RKH0100
and
Cable length ⇒ e.g. 30.5 m
Each string of distributed servo drives KSM must be terminated with the ter‐
minal connector.
Terminal connector
Fig.5-9:
Order Code of Terminal Connector
Parts of the installation with attached KSM/KMS must be connected to the
equipment grounding system of the installation. The housings of the
KSM/KMS then are connected to the equipment grounding system of the in‐
stallation via the flange. This connection is required in addition to the equip‐
Bosch Rexroth AG