Cabinet gas heater 4.2kw

Advertisement

3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH4200.V2
Fuel Type:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Butane
Gas Category:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Ignition:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Piezo
Heat Output (low): . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5kW/5.122Btu/hr
Heat Output (Medium):. . . . . . . . . . . . . . . . . . . . . . . . 2.8kW/9.562Btu/hr
Heat Output (High): . . . . . . . . . . . . . . . . . . . . . . . . . 4.2kW/14.343Btu/hr
Inlet Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-30mbar
Injector Size:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.62mm
Fuel Consumption (low): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110g/hr
Fuel Consumption (Medium): . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200g/hr
Fuel Consumption (High): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305g/hr
Flexible Hose:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BS3212 Type 2
Hose length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mm
fig.1
4. INSTALLATION
4.1.
Ventilation
4.1.1.
It is essential that adequate ventilation is provided and maintained in the room where the heater is installed. The heater needs a fresh
air supply to run efficiently. Ensure that any ventilation grilles in the room are open and not blocked. If there are no ventilation grilles,
a window or outside door will need to be opened. If the room begins to feel stuffy, more ventilation may be needed. See required room
ventilation opening below.
4.1.2.
DO NOT place the heater in a corridor or where it is likely to be exposed to strong draughts.
4.1.3.
The heater has an Oxygen depletion Sensor (OdS) fitted. This will shut the heater down if not enough fresh oxygen content is available.
4.1.4.
If the heater shuts down, DO NOT relight it until extra ventilation is sourced.
4.1.5.
The heater MUST NOT be used in rooms having less than 15m³ volume (30m³ for living rooms). See table below.
HEAT SETTING
MIn.
Med.
Max.
© Jack Sealey limited
A - Ignition button
B - Heat Control dial
C - Gas Regulator
d - Gas Cylinder Retainer
E - Gas Cylinder (not included)
F - Heater Grille
G - Ceramic Burner Panels
H - Pilot light
REQUIRED ROOM VOLUME
15m³
28.5m³
42m³
fig.3
Original Language Version
3B
REQUIRED ROOM VENTILATION OPENING
105cm²
105cm²
105cm²
fig.4
fig.2
fig.5
(Switch shown in position 3)
CH4200.V2 Issue: 1 - 12/06/15