Maximum Permissible Exposure Level (Mpel) - Honeywell IntuVue RDR-4000 Pilot's Manual

3-d automatic weather radar system with forward looking windshear detection
Hide thumbs Also See for IntuVue RDR-4000:
Table of Contents

Advertisement

IntuVue RDR-4000 Weather Radar Pilot's Guide

MAXIMUM PERMISSIBLE EXPOSURE LEVEL (MPEL)

FAA advisory circular AC 20-68B defines the method for determining
the MPEL boundary. All personnel should remain beyond the distance
indicated in the illustration below. Manufacturers are required to
calculate two distances; the MPEL boundary is determined by the
greater of these two distances. The first distance is the near field/far
field boundary which is the distance from the antenna that it takes for
the beam to form. For the RDR-4000 this distance is 14 ft
(4.27 meters). The second is the distance where the radiation level
exceeds the U.S. Government standard of 10 milliwatts per square
centimeter. For the RDR-4000 this distance is 11.8 ft (3.58 meters)
from the antenna. In TEST mode the system transmits two
550-microsecond pulses at the beginning of the test sequence and the
safe distance is 0.8 inches (2.1 centimeters) from the antenna during
this period. The safe fuel distance is 3.5 ft (1.07 meters) from the
antenna.