MICOM FUNCTION AND CIRCUIT DIAGRAM
5-3. Sensor Resistance Specification Chart
4
Sensor Common Difference is 5%.
4
For sensor resistance value measuring, the sensor must stay idle for more than 3 minutes before the measurement.
(Because of a sensing rate, a delay is necessary)
4
A digital tester is preferred. (an analog tester has greater error range)
4
For sensor measurement, separate MAIN Part CON4 HOUSING in PWB (PCB) ASSEMBLY. Referring to a circuit
diagram above, measure each sensor's terminal at a separated housing.
Temperature
Measurement (°C)
-20 °C [-4 °F]
-15 °C [+5 °F]
-10 °C [+14 °F]
-5 °C [+23 °F]
0 °C [+32 °F]
+5 [+41 °F]
+10 [+50 °F]
+15 [+59 °F]
+20 [+68 °F]
+25 [+77 °F]
+30 [+86 °F]
+40 [+104 °F]
+50 [+122 °F]
Top · Bottom Sensor, Top · Bottom EVA Sensor,
Exterior Sensor
77 KΩ
60 KΩ
47.3 KΩ
38.4 KΩ
30 KΩ
24.1 KΩ
19.5 KΩ
15.9 KΩ
13 KΩ
11 KΩ
8.9 KΩ
6.2 KΩ
4.3 KΩ
Exterior Sensor
Top EVA Sensor
Bottom EVA Sensor
- 23 -
Top Sensor
Bottom
Sensor