Mitsubishi Electric 800 Series Instruction Manual page 34

Hide thumbs Also See for 800 Series:

Advertisement

Available languages

Available languages

 CA type
Source logic
Main circuit terminal
Control circuit terminal
Three-phase
AC power
supply
Control input signals
(No voltage input allowed) 
Forward rotation start
Reverse rotation start
Start self-holding selection
Multi-speed
selection
Second function selection
Terminal 4 input selection
(Current input selection)
Common for external power
supply transistor
Contact input common
24 VDC power supply
24 V external power
Common terminal
Frequency setting signals (Analog)
Frequency setting
potentiometer
1/2W1kΩ 
Terminal 4 input
(Current input)
Connector for plug-in option connection
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common

For the FR-F820-03160(75K) or higher, the FR-F840-01800(75K) or higher, always connect a DC reactor (FR-HEL), which is available as an option. (To select a DC
reactor, refer to the Instruction Manual (Detailed), and select one according to the applicable motor capacity.)
When connecting a DC reactor, if a jumper is installed across terminals P1 and P/+, remove the jumper before installing the DC reactor. (The jumper is not installed for
the FR-F820-03160(75K) or higher and the FR-F840-01800(75K) or higher.)

When using separate power supply for the control circuit, remove the jumper between R1/L11 and S1/L21.

The function of these terminals can be changed with the input terminal assignment (Pr.178 to Pr.189). (Refer to the Instruction Manual (Detailed).)

Terminal JOG is also used as the pulse train input terminal. Use Pr.291 to choose JOG or pulse.

Terminal input specifications can be changed by analog input specification switchover (Pr.73, Pr.267). To input a voltage, set the voltage/current input switch OFF. To
input a current, set the voltage/current input switch ON. Terminals 10 and 2 are also used as a PTC input terminal. (Pr.561) (Refer to the Instruction Manual (Detailed).)

It is recommended to use 2 W 1 kΩ when the frequency setting signal is changed frequently.

Do not use terminals PR, PX, and P3. Availability of the jumper depends on the inverter model. (Refer to the Instruction Manual (Detailed).)

The function of these terminals can be changed with the output terminal assignment (Pr.195, Pr.196). (Refer to the Instruction Manual (Detailed).)

The function of these terminals can be changed with the output terminal assignment (Pr.190 to Pr.194). (Refer to the Instruction Manual (Detailed).)

No function is assigned in the initial status. Assign the function using Pr.186 CS terminal function selection. (Refer to the Instruction Manual (Detailed).)
NOTE
• To prevent a malfunction due to noise, keep the signal cables 10 cm or more away from the power cables. Also, separate the main circuit cables at the input side from
the main circuit cables at the output side.
• After wiring, wire offcuts must not be left in the inverter. Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean. When drilling mounting
holes in an enclosure etc., take caution not to allow chips and other foreign matter to enter the inverter.
• Set the voltage/current input switch correctly. Incorrect setting may cause a fault, failure or malfunction.
DC reactor
(FR-HEL) 
Jumper
Jumper 
Earth
(Ground)
P1
P/+
MC
MCCB
R/L1
Inrush current
S/L2
limit circuit
T/L3
ON
R1/L11
Jumper

S1/L21
OFF
Main circuit
Earth
(Ground)
Control circuit
STF
STR
STP(STOP)
RH
High speed
RM
Middle speed
RL
Low speed

JOG
Jog operation
RT
MRS
Output stop
RES
Reset
AU
CS

SD
24 V
PC
+24
supply input
SD
Voltage/current

input switch
ON
10E(+10 V)
OFF
10(+5 V)
2
3
0 to 5 VDC
Initial value
2
2
0 to 10 VDC selectable
0 to 20 mADC
5
1
(Analog common)
0 to ±10 VDC
Initial value
Auxiliary
(+)
1
0 to ±5 VDC selectable
(-)
input
4 to 20 mADC
Initial value
(+)
4
0 to 5 VDC
selectable
(-)
0 to 10 VDC
connector 1 connector 2
connector 3
Shorting
24 V
wire
PC
S1
Output shutoff
S2
circuit
SIC
SD
FR-F820-00770(18.5K) to 01250(30K),
FR-F840-00470(22K) to 01800(75K)
DC reactor
(FR-HEL) 
Brake unit
Jumper
(Option)
Earth
(Ground)
P1
P/+
Inrush
PX  PR  N/-
current
limit circuit
U
V
W
EMC filter
ON/OFF
connecter
Relay output 
C1
B1
Relay output 1
(Fault output)
A1
C2
B2
Relay output 2
A2
RUN
Open collector output 
Running
SU
Up to frequency
IPF
Instantaneous
power failure
OL
Overload
FU
Frequency detection
SE
Open collector output common
Sink/source common
PU
connector
F/C
(+)
(CA)
Analog current output
USB A
(0 to 20 mADC)
4
connector
(-)

USB
AM
(+)
Analog signal output
mini B
(0 to ±10 VDC)
connector
(-)
5

TXD+
Data
TXD-

transmission
RXD+
Data
RXD-
reception
GND
(SG)
GND
Terminating
5V
VCC
resistor
(Permissible load current 100 mA)
So (SO)
Safety monitor output
SOC
Safety monitor output common
Terminal connection diagrams
Brake unit
(Option)

PR  N/-
P3
Motor
M
Earth (Ground)
RS-485 terminals
WIRING
5