DC power cord for normal operation. 1.1 Safety precautions and • Please use approved power cord maintenance provided by Philips all the time. If your power cord is missing, please Warnings contact with your local service Use of controls, adjustments or center.
Page 4
1. Important tilt angle maximum is exceeded, the • Oil-based cleaning solutions may monitor damage will not be covered damage the plastic parts and void under warranty. the warranty. • Do not knock or drop the monitor • Unplug the monitor if you are not during operation or transportation.
1. Important Uninterrupted display of still or 1.2 Notational Descriptions static images over an extended The following subsections describe period may cause “burn-in”, also notational conventions used in this known as “after-imaging” or “ghost document. imaging”, on your screen. • “Burn-in”, “after-imaging”, or Notes, Cautions and Warnings “ghost imaging”...
From the planning, design and production stages, Philips emphasizes the important of making products that can easily be recycled. At Philips, end- of-life management primarily entails This marking on the product or on participation in national take-back...
2.1 Installation the screen. Attach/Slide the base column with the monitor until it Package contents clicks into position. 241V8/241V8W/241V8L/241i8L V Line 241V8/242V8/241i8 Quick Start Register your product and get support at www.philips.com/welcome 2.
Page 8
2. Setting up the monitor Connecting to your PC 242V8A/242V8LA 241V8/241V8W/241V8L/241i8L 2 3 4 AC power input AC power input DP input HDMI input HDMI input VGA input VGA input HDMI audio out Audio input Kensington anti-theft lock Earphone output...
2. Setting up the monitor 241V8LA/242V8A/242V8LA 2.2 Operating the monitor Description of the control buttons 241V8/241V8W/241V8L/241i8L Switch monitor’s power ON and OFF. Access the OSD menu. Confirm the OSD adjustment. Switch monitor’s power ON and OFF. Adjust the OSD menu.
Page 10
On-Screen Display. You can use On-Screen Display (OSD) is a feature this as a reference when you want to in all Philips LCD monitors. It allows an work your way around the different end user to adjust screen performance adjustments later on.
2. Setting up the monitor Resolution notification 2.3 Remove the Base Assembly This monitor is designed for optimal for VESA Mounting performance at its native resolution, Before you start disassembling the 1920 × 1080. When the monitor is monitor base, please follow the powered on at a different resolution, an instructions below to avoid any possible alert is displayed on screen: Use...
Page 12
2. Setting up the monitor Note This monitor accepts a 100mm x 100mm VESA-Compliant mounting interface. VESA Mounting Screw M4. Always contact manufacturer for wall-mount installation. 100mm 100mm 0° 90° -5° * Display design may differ from those illustrated. Warning • To avoid potential screen damage, such as panel peeling, ensure that the monitor does not tilt downward...
SmartImage is an exclusive, leading This mode significantly enhances edge Philips technology that analyzes readability and productivity when the content displayed on your screen. you're working with spreadsheets, Based on a scenario you select,...
Developed for wellbeing, content. SmartContrast dynamically Philips LowBlue Mode setting uses controls contrast and adjusts a smart software technology to backlighting for clear, crisp, bright reduce harmful shortwave blue gaming and video images or displays light.
Page 17
1.02 BTU/hr 1.02 BTU/hr 1.02 BTU/hr On mode: White, Standby/Sleep mode: White Power LED indicator (blinking) Power Supply Built-in, 100-240V AC, 50-60Hz Power (241V8L/241V8LA/241i8L) AC Input AC Input AC Input Consumption Voltage at Voltage at Voltage at 100VAC , 60Hz...
Page 18
540 x 322 x 51 mm (WxHxD) Product with packaging 608 x 415 x 121 mm (WxHxD) Weight 241V8/241V8W: 3.06 kg 241V8L/242V8A/241i8L: 3.03 kg Product with stand 241V8LA: 2.97 kg 242V8LA: 3.00 kg 241V8/241V8W: 2.66 kg 241V8L/242V8A/241i8L: 2.64 kg Product without stand 241V8LA: 2.58 kg...
Page 19
500 to 1060hPa (Non-operation) Environmental and energy ROHS Packaging 100% recyclable Specific Substances 100% PVC BFR free housing Cabinet Color White/Black Finish Texture Note This data is subject to change without notice. Go to www.philips.com/support to download the latest version of leaflet.
(Standby 0.5 W (blink) Off mode 0.3 W mode) Off mode 0.3 W 241V8L/241V8LA/241i8L Power Management Definition The following setup is used to measure power consumption on this monitor. VESA Power Video H-sync V-sync • Native resolution: 1920 × 1080...
Pixel Defect Policy sub pixels together appear as a single white pixel. When all are dark, the three Philips strives to deliver the highest colored sub pixels together appear as a quality products. We use some single black pixel. Other combinations...
Page 23
Red + Green = Yellow of the same type that are near to one Green + Blue = Cyan (Light Blue) another may be more noticeable, Philips also specifies tolerances for the proximity of pixel defects. Three adjacent lit sub pixels (one white pixel).
Page 24
In order to qualify for repair or replacement due to pixel defects during the warranty period, a TFT Monitor panel in a Philips flat panel monitor must have pixel or sub pixel defects exceeding the tolerances listed in the following tables.
Please contact our Philips Customer Service Representative or local contact center (by Consumer care number) for more details. Philips Customer Care Center number listed below.
• Contact with Philips customer • First, ensure that the power button service representative immediately. on the front of the monitor is in the...
Page 27
Service contact information listed in images over an extended period Important information manual and may cause "burn-in", also known as contact Philips customer service "after-imaging " or "ghost imaging", representative. on your screen. "Burn-in", "after- * Functionality different according to imaging", or "ghost imaging"...
Philips LCD monitor. the panel surface side. This may affect your warranty conditions. • Turn on your monitor and then turn on your PC.
Page 29
PC, workstation or Mac? may result in severe “burn-in” or “after- Ans.: Yes. All Philips LCD monitors are image” or “ghost image” symptoms fully compatible with standard that will not disappear and cannot be PCs, Macs and workstations.
Page 30
“Attention” to show the unlock/lock status as shown below illustrators. Q14: Where can I find Important Information manual mentioned in EDFU? Ans.: Important Information manual can be download on the Philips website support page..
Page 31
This product has been manufactured by and is sold under the responsibility of Top Victory Investments Ltd., and Top Victory Investments Ltd. is the warrantor in relation to this product. Philips and the Philips Shield Emblem are regis- tered trademarks of Koninklijke Philips N.V. and are used under license.