Installation Instructions
Wall
Isolation Through Wall
Figure 13
7 Refrigerant Line Brazing
7.1 Braze The Refrigerant Lines
1.
Remove caps or plugs. Use a deburring tool to deburr the pipe ends. Clean
both internal and external surfaces of the tubing using an emery cloth.
Figure 14
Bosch Thermotechnology Corp. | 10.2020
Sealant
Insulation
Suction Line
DO NOT hang linesets from ductwork
Bosch IDS BOVB 18 | 11
Ductwork
Isolator
Lineset