Bosch 70 Series Instruction Manual page 33

Axial piston fixed motor
Table of Contents

Advertisement

Port overview
Table 10: Ports A2FM/A2FE Series 70
Ports
1)
A, B
Working port
T
Drain port
1
T
Drain port
2
Fig. 10: Port overview A2FM, SAE flange ports on side
Fig. 11: Port overview A2FE, SAE flange ports on side
A2FMn/A2FEn
350
3
3
1)
The measuring system and thread size can be taken from the installation drawing.
2)
Depending on the application, short-term pressure peaks can occur. Keep this in mind when
selecting measuring equipment and fittings.
Depending on the installation position, T
3)
"Installation position" on page 26)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
T
1
T
B
2
T
1
T
B
2
p
[bar]
2)
max
A2FMM/A2FEM
450
3
3
or T
must be connected (see chapter 7.3
1
2
RE 91071-01-B/03.2015, A2FM/A2FE Series 70, Bosch Rexroth AG
Installation
33/52
A
A
Status
A2FMH/A2FEH
500
O
3
O
3)
3
X
3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a2fmA2fe

Table of Contents