Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instructions
gloves
1. SAFETY
Familiarise yourself with the applications, limitations and hazards of the press.
9
Maintain the press in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Keep the press clean for best and safest performance.
9
Locate the press in an adequate working area for its function, keep area clean and tidy and free from unrelated materials and ensure
9
there is adequate lighting.
Ensure the workpiece is correctly secured before operating the press.
9
Ensure that all fittings are tight before each use.
9
Remove ill fitting clothing. Remove ties, watches, rings, other loose jewellery and contain long hair.
9
Keep hands and body clear of the table when operating the press.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
Securely attach the press to a flat, firm, level surface capable of supporting the weight of press and any workpiece taking into account
9
clearance for workpieces.
When not in use, release pressure from the hydraulic unit and clean the press. Stand or store the V blocks in a safe location.
9
DO NOT operate the press if any parts are missing as this may cause failure and/or possible personal injury.
8
DO NOT use the press for a task it is not designed to perform.
8
DO NOT make any modifications to the press.
8
DO NOT exceed the rated capacity of the press.
8
DO NOT apply off-centre loads.
8
DO NOT allow the workpiece or the v blocks to fall from the table.
8
DO NOT get the press wet or use in damp or wet locations or areas where there is condensation.
8
DO NOT operate the press when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT climb upon the press.
8
DO NOT use the press to compress a spring or any other item that could disengage and cause a potential hazard including personal
8
injury.
DO NOT stand directly in front of a loaded press and never leave a loaded press unattended.
8
DO NOT allow untrained persons to operate the press.
8
WARNING! Always wear approved eye or face protection when operating the press. A full range of personal safety equipment is
available from your Sealey stockist.
WARNING: DO NOT top up hydraulic unit with brake fluid, or any other fluid other than a good quality hydraulic oil (Sealey Part
Number: HJO500MLS/HJO5LS) as this may cause serious damage to the hydraulic unit and will invalidate the warranty.
WARNING! Always position the press against a wall. If the press is situated in the open workshop, it is essential that a guard
be placed at the rear of the unit. This will prevent injury to bystanders in the event of the work piece ejecting suddenly.
WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that may
occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this
product, but must be applied by the operator.
DANGER! The press is top heavy. If it requires moving after assembly or for relocation, use suitable slings around the top
crossbeam, or lift direct with a forklift with the forks located under the top crossbeam. DO NOT use a pallet truck.
2. INTRODUCTION
Steel frame construction with side mounted, air motor powering hydraulic pump unit. Sliding hydraulic ram assembly giving 403mm of lateral
travel for off-centre pressing applications. Fitted with ram pressure gauge and supplied with flat pressing plate/V-blocks.
© Jack Sealey Limited
20TONNE FLOOR TYPE AIR/HYDRAULIC
PRESS
MODEL NO:
Wear safety
Wear protective
clothing
footwear
Original Language Version
YK20FAH.V3
Wear face
Warning:
Crushing of
Shield
Hands
YK20FAH.V3 Issue 2 (3) 12/10/2021

Advertisement

loading

Summary of Contents for Sealey YK20FAH.V3

  • Page 1 ‰ available from your Sealey stockist. WARNING: DO NOT top up hydraulic unit with brake fluid, or any other fluid other than a good quality hydraulic oil (Sealey Part ‰ Number: HJO500MLS/HJO5LS) as this may cause serious damage to the hydraulic unit and will invalidate the warranty.
  • Page 2 Air operating system: open the release valve by turning it counter-clockwise. Connect the air inlet fitting into the air supply hose lock fitting, then turn on the air valve letting the pump work for several times to eliminate any air in the system. fig.1 Original Language Version YK20FAH.V3 Issue 2 (3) 12/10/2021 © Jack Sealey Limited...
  • Page 3 7. MAINTENANCE NOTE: Maintenance and repair must only be carried out by qualified person. Contact your Sealey stockist for details. 7.1. When the press is not in use, the hydraulic unit ram must be fully retracted to minimise corrosion. Remove the handle to inactivate the press.