Clean Fuel Solenoid Pump Strainer - Hitachi 120-3 class Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

5

Clean Fuel Solenoid Pump Strainer

--- every 500 hours
Cleaning
When the strainer is disassembled, be sure to replace the
gasket. Install the cover and the magnet only after suffi-
ciently cleaning them. After being assembled, closely check
the air-tightness of the strainer.
Disassembling/ Assembling
To remove cover (1), loosen with a spanner. After the cover
is removed, gasket (2), strainer (3), and gasket (4) are easily
removed in order. Wash removed strainer (3) with light oil.
Install the strainer in the reverse order of disassembling. At
that time, install gasket (2) into cover (1) first. Then, securely
tighten cover (1) to pump (5) using a spanner.
NOTE: Wrench size: 17 mm
Magnet
1
2
36 mm
3
28 mm
MAINTENANCE
3
4
5
M1GR-07-004
2.7 mm
1 mm
2
M1U1-07-006
Fuel Solenoid Pump
4
Fuel Solenoid Pump
7-51
ZX120-3 Class
Fuel Solenoid
Pump
ZX180-3 Class
ZX200-3, 270-3 Class
ZX330-3 Class
M1U1-07-103
M1U1-07-098
Fuel Solenoid
Pump
M1U1-07-071
M1U1-07-074