Fujitsu Comfort Series Service Manual page 7

Hide thumbs Also See for Comfort Series:
Table of Contents

Advertisement

1. Specifications
1-1. Outdoor unit
¢ Nominal capacity and nominal input
Model name
Power supply
-15°C/+45°C
-10°C/+55°C
-10°C/+35°C
-7°C/+35°C
-7°C/+55°C
COP priority
+2°C/+35°C
Capacity priority
+7°C/+35°C
+7°C/+45°C
+7°C/+55°C
NOTE: Test conditions are complied with EN14511-2
1-1. Outdoor unit
Hydraulic indoor unit
Outdoor unit
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Minimum
Heating capacity
Nominal
Maximum
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
Heating capacity
Nominal
Input power
Nominal
COP
Nominal
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
- (01-1) -
WSYA100ML3
WOYA100KLT
1 Ø 230 V ~ 50 Hz
7.50
3.75
2.00
7.10
4.06
1.75
8.20
3.35
2.45
8.90
3.36
2.65
8.00
4.10
1.95
4.50
1.14
3.95
9.30
3.08
3.02
3.56
9.50
15.29
2.11
4.50
9.00
2.475
3.45
9.00
3.33
2.70
1. Specifications

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comfort woya100kltComfort wsya100ml3

Table of Contents