14. Glossary

R
Expert Mode: Supporting messages are displayed
on the screen for each individual action step.
R
Combo filter: Filter and dryer cartridge for
removing fine particles and moisture from the
refrigerant.
R
PS2 stick:
Storage medium with PS2 connection; used in
order to perform software update of ACS 810, or to
store data from the internal memory of ACS 810 for
data management on a PC.
R
Recovery phase:
The refrigerant is removed from the vehicle air
conditioner using suction, cleaned and routed into
the internal vessel of the ACS 810. The refrigerant
oil collected in the process is drained into the used
oil bottle at the ACS 810.
R
Vacuum phase:
A vacuum is generated in the vehicle air
conditioning system. Measurement of the drop in
pressure commences as soon as the vacuum has
been generated.
R
Fresh oil refill phase:
Fresh oil is added to the vehicle air conditioner.
R
Filling phase:
A certain quantity of refrigerant is added to the
vehicle air conditioner.
Robert Bosch GmbH
Glossary | ACS 810 | 65 |

15. Technical data

15.1

ACS 810

Property
Dimensions H x W x D
Weight
Operating voltage
Frequency
Workplace emission sound pressure
level as per EN ISO 11204
Refrigerant
Low-pressure gauge
High-pressure gauge
Capacity of internal refrigerant cylinder
Safety class
Power output
15.2

Ambient temperature

Property
Storage and transport
Operation
15.3

Air humidity

Property
Storage and transport
Operation
15.4

Electromagnetic compatibility

This product complies with the standards EN 61000-3-
2 and EN 61000-3-3.
en
Value/range
1270 x 690 x 660 mm
120 kg
230 VAC ± 10 %
50 Hz
< 70 dB(A)
R134a
-1 bar – 16 bar ± 1 %
-1 bar – 40 bar ± 1%
40 l
IP 20
1300 W
Value/range
-25 °C – 60 °C
-13 °F – 140 °F
10 °C – 45 °C
50 °F – 113 °F
Value/range
<75 %
<90 %
|
1 689 989 601
2020-12-01