Technical Instructions; Installation - LG CBGZ2414S Owner's Manual

Table of Contents

Advertisement

Injector for LPG G30 29 mbar (CBGZ2414S 4 ea, CBGZ3016S 5ea)
d
LPG Gas Pipe Elbow (1 ea, 1 ea)
e
Seal (3 ea)
f
g
LNG Gas Pipe Elbow (1 ea)

Technical Instructions

Technical Instructions
WARNING
• Do not modify this appliance.
• This appliance must be installed by an
authorised technician or installer.
• Prior to installation, ensure that the local
distribution conditions (nature of the gas and
gas pressure) and the adjustment of the
appliance are compatible.
• The adjustment conditions for this appliance are
stated on the label (or data plate).
• This appliance is not connected to a combustion
products evacuation device. It should be
installed and connected in accordance with
current installation regulations. Particular
attention should be given to the relevant
requirements regarding ventilaton.
• The device shall not be operated for more than
15 seconds. If after 15 seconds the burner has
not lit, stop operating the device and open the
compartment door and/or wait at least 1 minute
before attempting a further ignition of the
burner.
• Before installing, turn off the gas and electricity
supply to the appliance.
• All appliances containing any electrical
components must be earthed.
• Ensure that the gas pipe and electrical cable are
installed in such a way that they do not touch any
parts of the appliacne which may become hot.
• Gas pipe or connector should not be bent or
blocked by any other appliances.
• Check the dimensions of the appliance as well as
the dimensions of the gap to be cut in the
kitchen unit.
• The panels located above the work surface,
directly next to the appliance, must be made of
nonflammable material. Both the stratified
surfacing and the glue used to secure it should
be heat resistant to prevent deterioration.
• Turn on appliance tap and light each burners.
Check for a clear blue flame without yellow
tipping.
If burners show any abnormalties, check the
following :
- Burner lid positioned correctly
- Flame spreader positioned correctly
- Burner vertically aligned with injector nipple
• A full operational test and a test for possible
leakages must be carried out by the technician
after installation.
• The fiexible hose shall be fitted in such a way that
it cannot come into contact with a moveable part
of the housing unit and does not pass through
any space susceptible of becoming congested.

Installation

Dimensions and Clearances
This appliance is to be built into a kitchen unit or
600 mm worktop, providing the following
minimum distances are allowed;
• The edges of the hob must be a minimum
distance of 60 mm from a side or rear wall.
• 700 mm between the highest point of the hob
surface including the burners and the underside
of any horizontal surface directly above it.
• 400 mm between the hob surfaces, providing
that the underside of the horizontal surface is in
line with the outer edge of the hob. If the
underside of the horizontal surface is lower than
INSTALLATION
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbgz3016s

Table of Contents