Download Print this page
Sealey SAC5020E.V2 Quick Start Manual

Sealey SAC5020E.V2 Quick Start Manual

Compressor 50ltr direct drive 2hp

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE THE PROdUCT
CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd. FAiLURE TO dO SO MAY CAUSE dAMAGE ANd/OR PERSONAL iNJURY ANd WiLL
iNvALidATE THE WARRANTY. KEEP THESE iNSTRUCTiONS SAFE FOR FUTURE USE.
1.
SAFETY iNSTRUCTiONS
1.1.
ELECTRiCAL SAFETY
 WARNiNG! It is the responsibility of the owner and the operator to
read, understand and comply with the following: You must check all
electrical products, before use, to ensure that they are safe. You must
inspect power cables, plugs, sockets and any other connectors for
wear or damage. You must ensure that the risk of electric shock is
minimised by the installation of appropriate safety devices. A Residual
Current Circuit Breaker (RCCB) should be incorporated in the main
distribution board. We also recommend that a Residual Current device
(RCd) is used. It is particularly important to use an RCd with portable
products that are plugged into a supply which is not protected by an
RCCB. If in any doubt consult a qualified electrician. You may obtain a
Residual Current device by contacting your Sealey dealer. You must
also read and understand the following instructions concerning
electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance Tester
(PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators. if in any
doubt about electrical safety, contact a qualified electrician.
1.1.3. ensure that the insulation on all cables and on the appliance is
safe before connecting it to the power supply. See 1.1.1. and
1.1.2. and use a Portable Appliance Tester.
1.1.4. ensure that cables are always protected against short circuit
and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none is loose.
1.1.6. important: ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is fitted
with the correct fuse - see fuse rating at right.
1.1.7. dO NOT pull or carry the appliance by the power cable.
1.1.8. dO NOT pull the plug from the socket by the cable.
1.1.9. dO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician. When a BS 1363/A UK 3 pin plug is
damaged, cut the cable just above the plug and dispose of the
plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth
terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that
all wires have been correctly connected, that the cable outer
insulation extends beyond the
cable restraint and that the
restraint is tight.
double insulated products, which
are always marked with this
symbol
, are fitted with live
(brown) and neutral (blue) wires
only. To rewire, connect the wires
as indicated in diagram.
dO NOT connect either wire to the
earth terminal.
1.1.10. Products which require more than
13 amps are supplied without a
plug. In this case you must contact
a qualified electrician to ensure
that a suitably rated supply is
available.
© Jack Sealey limited
COMPRESSOR 50LTR diRECT dRivE 2HP
SAC5020E.v2
model No:
RECOMMENdEd
FUSE RATiNG: 13 AMP
Original Language Version
Guide to symbols
Warning: electricity
Warning: Hot Surface
Warning: Automatic
start up
Wear ear protection
Read the instruction
manual before use
We recommend that you discuss the installation of an industrial
round pin plug and socket with your electrician.
iMPORTANT! The use of extension leads to connect these
compressors to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump performance.
1.2.
GENERAL SAFETY
3
Familiarise yourself with the application and limitations of the
compressor.
3
ensure the compressor is in good order and condition before
use. If in any doubt do not use the unit and contact an
electrician/service agent.
WARNiNG! Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to
adjust, pressure switch or safety valve.
3
Before moving, or maintaining the compressor ensure it is
unplugged from the mains supply and that the air tank pressure
has been vented.
3
maintain the compressor in good condition and replace any
damaged or worn parts. Use genuine parts only. Unauthorised
parts may be dangerous and will invalidate your warranty.
3
Read the instructions relating to any accessory to be used
with this compressor. ensure the safe working pressure of any
air appliance used exceeds compressors output pressure.
If using a spray a gun, check that the area selected for spraying
is provided with an air change/ventilation system.
3
ensure the air supply valve is turned off before disconnecting
the air supply hose.
3
To move the compressor use the handle only. maintain unit's
centre of gravity when lifting. dO NOT attempt to lift or move
the compressor by any other means.
3
Use the compressor in a well ventilated area and ensure it is
placed on a firm surface.
3
Keep tools and other items away from the compressor when
it is in use, and keep area clean and clear of unnecessary
items.
3
ensure the air hose is not tangled, twisted or pinched.
dO NOT open the air
cock before an air hose
is attached
dO NOT operate the
compressor with
enclosure displaced
ensure oil level is
correct before first use
SAC5020e.V2 Issue No:4 (dofC) 26/03/18

Advertisement

loading

Summary of Contents for Sealey SAC5020E.V2

  • Page 1 SAC5020E.v2 model No: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE THE PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd.
  • Page 2 (fig.3.6) will activate. up in the crankcase causing damage to the compressor and possible personal injury. 3.6. Fit the air filter into the inlet port if required (fig.4). Original Language Version © Jack Sealey limited SAC5020e.V2 Issue No:4 (dofC) 26/03/18...
  • Page 3 NOT overfill. Replace plug (fig.2A). Recommended oil for compressors, Suitable for room temperatures ranging from +5ºC to +25ºC. SeAleY CPo or equivalent SAe 40 compressor oil. Room temperature below +5ºC: SAe 20 compressor oil.
  • Page 4 (Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. iP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...