5. MAINTENANCE
WARNING! Ensure the cabinet is disconnected from the electrical mains and the air supply before attempting any
maintenance.
5.1.
Ensure the blasting media does not become damp. Keep the air supply dry at all times. Dispose of any damp media.
5.2.
Replace media when it has become excessively dusty, loses its granular or spherical appearance, or is significantly contaminated
with debris from workpieces. This is usually noticed when media from the nozzle looks like a smoke cloud rather than steam.
5.3.
Regularly check that the exhaust vents at the side and rear of the cabinet are clear.
5.4.
Regularly check gun blast nozzle to ensure it does not become blocked with media. Immediately replace worn or damaged nozzle.
5.5.
If abrasive pick-up hose becomes blocked, cover the gun tip to force air back through the hose. Ensure the lid is correctly closed.
5.6.
Replace the transparent protective sheet on the underside of the Perspex window when visibility becomes reduced.
6. TROUBLESHOOTING
PROBLEM
Excessive dust in the cabinet.
Uneven blasting.
Inadequate speed or efficiency of blast.
Static electricity.
Blast pattern too wide or ineffective.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
POSSIBLE CAUSE
1. Exhaust vent or air flow is blocked.
2. Abrasive is worn.
3. Too much abrasive in the cabinet
4. Loose air line or fittings.
1. Too much abrasive in cabinet.
2. Moisture inside cabinet.
1. Abrasive is worn.
2. Pressure is too low.
1. Dry weather conditions.
1. Nozzle blocked or worn.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
REMEDY
1. Clean vent and keep vent away from any wall.
Connect to a suitable dust extraction system.
2. Replace.
3. Remove excess.
4. Check and tighten all air fittings.
1. Remove excess.
2. Check air line for moisture.
1. Replace.
2. Check that there are no supply blockages or leaks.
Increase pressure. Max:90psi
1. Leave the workpiece to stand for a while.
1. Unblock or replace nozzle