en | Appendices
8.2

Requirements in accordance with EN 50131 grade 3

Notice!
If not all requirements in accordance with this standard can be satisfied or only a lower grade
can be met, the compliance mark (EN 50131 grade 3) must be either removed or adapted.
8.2.1

Selecting the default setting

1.
2.
8.2.2

Connectable peripherals

To comply with the requirements for proper functioning of the panel (i.e. detection and
forwarding of intrusion, hold-up, tamper and trouble states), only peripherals may be
connected that are certified in accordance with EN 50131 grade 3 or grade 4.
8.2.3

Arming / disarming without entry / exit delay

Arming outside the secured area, e.g. with arming device
1.
2.
3.
4.
5.
Programming two outputs for signaling the armed / disarmed state
1.
2.
3.
Securing access route against unauthorized entry in armed state, e.g. by installing a
blocking element
1.
2.
3.
4.
8.2.4

Arming / disarming with entry / exit delay

Arming inside the secured area, e.g. with control center
1.
2018.08 | 23 | F.01U.168.332
Select EN50131 grade 3 as the default property values setting (refer to Standard-
compliant programming, page 58).
If the panel validation in accordance with EN 50131 grade 3 fails, do not proceed with
programming the panel.
Include a new area if not yet present.
Connect a free input with the device key switch.
Using the wizard, select the type Static or Dynamic, the user and function of the key
switch Arm / Disarm Area. Now select the area that is to be armed / disarmed. For exit
delay, select No Delay.
Select the area in the properties field of the Key Switch > Area.
In the properties field of the Control Center, include the area in the scope Local Area or
Additional Areas in Scope
Connect one free output in each case with the device LED.
Using the wizard, program one output with the behavior item Area Armed and a second
output with the behavior item Area Disarmed.
The signal must be time-limited. Enter a corresponding time (typically 10 sec. / maximum
30 seconds) for Activation Duration.
Connect a free output with the device LED.
Variant A: Blocking element is actively controlled CLOSED. Using the wizard, program an
output with the behavior item Area Armed
or
Variant B: Blocking element is actively controlled OPEN. Using the wizard, program an
output with the behavior item Area Disarmed.
The signal must be static; enter 00:00:00 for Activation Duration.
Refer to the manufacturer's connection instructions for further information.
Include a new area if not yet present.
Installation manual