STANDARD FLUE HORIZONTAL
MIN 250 mm A x 1*
* Requires cutting
MAXIMUM FLUE HORIZONTAL
i
*
0100-10000 mm
Ax 1 + B x 10
0125-23000 mm
A x 1 + B x 23
MAXIMUM FLUE VERTICAL START + 1 BEND
Ffi H
I
I
1
B
O
C
0100 -10000 mm
A x 1 + C x 1 + B x 11
+ Fx1
0125-23000 mm
A x 1 + C x 1 + B x 23
+ F x 1
MAXIMUM FLUE HORIZONTAL + 1 BEND
Q i
I te 7 A
I ... - .................
B
c
O
0100-8000 mm
Ax1+ Bx9 + Cx1
0125-21000 mm
A x 1 + B x 21 + C x 1
^WORCESTER
INSTALLATION & SERVICIN
6 720 611 927b (04/05)
Bosch
roup
MAXIMUM FLUE VERTICAL
START +2 BENDS
â. a
1 1
/
f
ii
pa
I
■
b
cQ
0100 - 8000 mm
Ax 1 +0x2+ B x 10
+ Fx1
0125-21000 mm
Ax 1 + Cx 2 + B x 22
+ Fx1
MAXIMUM FLUE VERTICAL
START + 3 BENDS
F
S.
B
EZ
c
0
0100 - 6000 mm
Ax 1 +Cx3
+ Bx9 + Fx1
0125 - 19000 mm
A x 1 + C x 3
+ B x 21 + F x 1
MAXIMUM FLUE VERTICAL
VERTICAL FLUE WITH
2X90° BENDS
C
0
0100-7500 mm
(including terminal)
Bx9+ Cx2 +Ex1
0125 - 19000 mm
(including terminal)
Bx20+ Cx2 +Ex1
INSTRUCTIONS FOR WORCESTER BOSCH
REENSTAR 25CDI/30CDÍ/35CDÍ/40CDI
FLUE OPTIONS 25CDi
•
The diagrams (opposite) show the compo
nents used and the maximum flue length for
each configuration of 100 mm and
125 mm 0 flues.
•
Shaded flue components indicate the stan
dard 100 mm 0 horizontal flue.
•
Only straight flue sections can be reduced
in length and cut.
•
The flue terminal end can be fitted from the
inside or outside of the building.
•
Fixing kits are supplied with the flue exten
sion kits.
•
Horizontal 125 mm 0 and Vertical 100 mm
and 125 mm 0 flue kits are available with
separate instructions. Contact your supplier
or Worcester Bosch.
A
Q t ....
~TT P
B
I ■
A - Standard horizontal flue (100 mm 0 shown)
B - Straight flue extension
C - Flue bend, 90*
D - Flue bends, 45°
E - Vertical terminal (vertical adaptor supplied
with terminal)
F • Vertical adaptor (used with horizontal
terminal)
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Horizontal 60/100 mm 0: 10000 mm
Horizontal 80/125 mm 0: 23000 mm
Vertical 60/100 mm 0: 11500 mm
Vertical 80/125 mm 0: 23000 mm
Then reduce the total straight flue length for
each extra flue bend (excluding the turret) by:
2000 mm for 90°
1000 mm for 45°
Flue extension total lengths:
Horizontal & Vertical 60/100 mm 0: 960 mm
Horizontal & Vertical 80/125 mm 0: 1000 mm
Flue terminal total lengths:
Horizontal 60/100 mm 0: 800 mm
Horizontal 80/125 mm 0: 1200 mm
Vertical 60/100 mm 0: 1140 mm
Vertical 80/125 mm 0: 1365 mm
6 720 611 927'06.10
C
Q
.
23
FLUE OPTIONS 25CDÍ