Cleaning the Air
Filter
The air filter should be cleaned whenever
you replace the lamp.
Remove the air filter, and then remove the
dust with a vacuum cleaner.
The time needed to clean the air filter will
vary depending on the environment or how
the projector is used.
1
Turn the power off and unplug the
power cord.
2
Remove the air filter covers.
The air filter of the VPL-FX41/FW41 is
on one side
3
Remove the air filter from the each
claws (6 positions) on the air filter
cover.
4
Clean the air filter with a vacuum
cleaner.
44

Cleaning the Air Filter

only.
Claws
5
Attach the air filter so that it fits into
the each claws (6 positions) on the air
filter covers and replace the cover.
Caution
If you neglect to clean the air filter, dust may
accumulate, clogging it. As a result, the
temperature may rise inside the unit,
leading to a possible malfunction or fire.
Notes
• If the dust cannot be removed from the air
filter, replace the air filter with a new one.
For details on new air filter, consult with
qualified Sony personnnel.
• Be sure to attach the air filter cover firmly;
the power can not be turned on if it is not
closed securely.
• The air filter has face and reverse sides.
Attach the air filter so that the frames on the
air filter are visible.
• To erase a message, press any key on the