LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
5019 319 62145
PRODUCT DESCRIPTION SHEET
1.
Removable pan grid
2.
4 rings burner
4 rings burner knob
3.
SYMBOLS
Tap closed
Maximum flame
Minimum flame
.
Burner
Pot Ø
4 rings burner
from 24 to 26 cm
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE
Type of gas used
Type of burner Ø injector
NATURAL GAS
4 ring
139
(Methane)
G20
LIQUID
PETROLEUM GAS
4 ring
95
(Butane)
G30
(Propane)
G31
Type of gas
Configuration
Rated thermal
used
model
flow rate kW
G20 20 mbar
1 burner
3.50
G30/G31 30 mbar
1 burner
3.50
ELECTRIC SUPPLY: 230 V - 50 Hz
GB
CZ
SK RO RU
BG
LT LV EE
CATEGORY II2H3B/P
Rated thermal
Rated
Reduced heat
Gas pressure (mbar)
flow rate kW
consumption
capacity kW
min.
3.50
333 l/h
1.50
17
3.50
254 g/h
1.50
25
Total rated
Air necessary (m
consumption
combustion of 1 m
333 l/h
9.52
254 g/h
30.94
SL
rat.
max.
20
25
30
35
3
) for the
3
of gas

Advertisement

loading

Summary of Contents for Whirlpool AKT 305 IX

  • Page 1 AKT 305 IX PRODUCT DESCRIPTION SHEET SK RO RU LT LV EE Removable pan grid DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm) 4 rings burner 4 rings burner knob SYMBOLS Tap closed Maximum flame Minimum flame LIGHTING THE BURNERS •...
  • Page 2 Ensure that the installation and gas connections are performed by a qualified technician, following the manufacturer's intend to install an oven beneath the hob, make sure that it is manufactured by Whirlpool and equipped instructions and in compliance with current local safety regulations.