Download Print this page

Sealey PC2950.V3 Instructions

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
p WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.
A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected
by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
1.1.1
electrician, using a Portable Appliance Tester (PAT), at least once a year.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
1.1.2
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4
Ensure that cables are always protected against short circuit and overload.
1.1.5
Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
Important: Ensure that the voltage marked on the appliance matches the power supply
1.1.6
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
DO NOT pull or carry the appliance by the power cable.
1.1.7
DO NOT pull the plug from the socket by the cable.
1.1.8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
1.1.9
item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK
3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation
extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure that a
suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.
1.1.11 If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of
2.5mm
section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.
2
1.2
GENERAL SAFETY
WARNING! Water and Electricity are dangerous partners. Be extremely cautious and always be aware that this device uses an
p
electric motor. Always plug into a RCD (see electrical safety above). Unplug from mains before changing accessories or servicing.
WARNING! DO NOT USE the washer if any part of the unit, gun, nozzle, detergent bottle, hose or cables is damaged. Replace or
p
repair using genuine parts only. Un-authorised parts may be dangerous and will invalidate your warranty. Always check connections
are correctly secured and not cracked or damaged in any way before using the machine.
WARNING! Use washer on a flat, levelled surface, in a vertical position. Failure to do so will invalidate your warranty. NEVER
p
lay the washer down during use.
Always be aware of the potential hazards that may occur during use. Study the applications and limitations of the washer before use.
4
Keep the washer in good condition. Use an authorised agent to service the unit.
4
Wear adequate protective clothing, goggles and anti-slip rubber soled footwear.
4
Use where air can freely circulate around the washer to avoid the machine over-heating.
4
WARNING! Ensure all persons and animals keep at a minimum distance of 16 yards (15mtr ) from the washer when in use.
p
WARNING! The pressure washer must only be used with clean water. Non-filtered water or corrosive chemicals must not be used as
p
they will damage the cleaner.
Ensue you comply with all local water supply regulations. Power washers may only be connected to mains drinking water supply
4
if a valve to prevent back flow is installed in the supply hose, or at the tap outlet.
Position the washer as near to the water supply as possible.
4
The supply hose must must be reinforced, and have an internal diameter of 1/2”. The water supply must be at least equal to the cleaner
4
capacity. The water temperature must NOT exceed 122
Ensure the nozzle is aimed correctly at the working surface before activating the jet.
4
Before operating the trigger, GRIP the gun firmly to counteract the recoil from the high pressure water jet.
4
WARNING! Avoid sudden bursts of water as such will cause water pressure to drop and put extreme pressure on hoses and connectors.
p
If, during operation, power failure occurs turn the electricity and water off for safety reasons.
4
WARNING! The high pressure jet will cause loose particles to be propelled at high speed, which may cause serious injury.
p
INSTRUCTIONS FOR:
PRESSURE WASHER
MODEL NO:
, are fitted with live (brown) and neutral (blue) wires only.
F (50
C). The water supply pressure must NOT exceed 145psi (10 bar).
O
O
PC2950.V3
Yellow & Green
Earth Wire
Blue
Neutral
Wire
FUSE RATING 13 AMP
, but to be absolutely sure that the
2
PC2950.V3 - 1 - 170105
Brown
Live
Wire
Cable
Restraint

Advertisement

loading

Summary of Contents for Sealey PC2950.V3

  • Page 1 PC2950.V3 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 Gun and hose assembly Supply hose quick connector ON/OFF switch Turbo nozzle with lance High pressure hose connector Detergent dispen ser Water plug Water inlet High pressure outlet Water inlet filter screen Cable tidy PC2950.V3 - 1 - 170105...
  • Page 3: Operation

    3.2. SPECIFICATION Motor Type ....Induction Total Stop ..... . .Yes Manifold Pressure .
  • Page 4: Maintenance

    Connection to power supply. The washer should be used in conjunction with an RCD safety cut-out device as indicated in fig.9. ( An RCD can be purchased from your local Sealey dealer.) Plug the RCD into the mains supply and plug the washer into the RCD.
  • Page 5: Troubleshooting Guide

    Contact Service Agent. DECLARATION OF CONFORMITY Declaration of Conformity We, the sole importer into the UK of Sealey Power Products, declare that the product listed below is in conformity with the following standards and directives. The construction file for this product is held by the Manufacturer and may Pressure Washer Model PC2950.V3...