AIR COMPRESSOR 2-gallon Oil Lubricated Model No. 921.153120 CAUTION: Before using this product, read this manual and follow all its Safety Rules and Operating Instructions. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com 08/11/2006 Part No. E102346 ®...
Español ..............10 ONE YEAR FULL WARRANTY ON CRAFTSMAN AIR COMPRESSOR If this Craftsman Air Compressor fails due to manufacturer’s defects in material or workmanship within one year of the date of purchase, RETURN IT TO THE NEAREST SEARS STORE OR SERVICE CENTER IN THE UNITED STATES and it will be replaced or repaired (at our option), free of charge.
The information listed below should be read and understood by the operator. This information is given to protect the user while operating and storing the air compressor. We utilize the symbols below to allow the reader to recognize important information about their safety.
Duty Cycle This is a 50% duty cycle air compressor. Do not run the air compressor more than 30 minutes of one hour. Doing so could damage the air compressor. Air Tank Capacity ......2 Gallons Cut-in Pressure .
The pressure relief valve located on the side of the pressure switch, is designed to automatically release compressed air when the air compressor reaches cut-out pressure. The released air should only escape momentarily and the valve should then close. Pressure Relief Tube...
Estimated Assembly Time: Approximately 5 minutes Getting Started - Location of the Air Compressor The air compressor should always be located in a clean, dry and well ventilated environment. The unit should have at minimum, 12 inches of space on each side. The air filter intake should be free of any debris or obstructions.
PSI settings. 9. The air compressor is now ready for use. The following inflation and cleaning accessories packaged with this unit should only be operated at maximum pressure of 90PSI: blow gun, rubber-tapered nozzle, inflation needles, adapter, and blow gun adapter.
Troubleshooting Guide The air compressor should be turned off and unplugged from the power source before any maintenance WARNING is performed as well as the air bled from the tank and the unit allowed time to cool. Personal injuries could occur from moving parts, electrical sources, compressed air, or hot surfaces.