Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Warning:
Refer to
Explosive
Instruction
material
Manual
1. SAFETY
IMPORTANT WARRANTY INFORMATION: KEEP YOUR ROADSTART HEALTHY

Read and understand the general safety and operating instructions before use. The following information is intended to help you
keep the product in top working order.
NOTE: – The battery in this unit is a consumable item and its ability to accept charge will reduce over time. We will provide warranty
against mechanical and electrical defect for a period of one year - this does not cover fair wear and tear.
If the battery is not charged properly before first use, or regularly conditioned, its capacity will diminish. Under these circumstances we
will not replace the battery even if it is less than one year old.

You can help prolong the life of the battery by following a few simple guidelines.

Plug in your new Roadstart to the mains transformer and make an INITIAL charge lasting 38 hours.

Ensure the unit is fully charged before storage.

DO NOT leave the Roadstart for longer than 2 months without putting it on charge.

DO NOT attempt to start a vehicle when the Roadstart battery level lights show red.

DO NOT drop or roughly handle the Roadstart – this will break or disjoin the battery terminals rendering the battery useless and the
warranty void.

DO NOT use any other charger, other than the one supplied, to recharge the battery.

DO NOT obstruct the ventilation grilles and protect against water ingress - The RoadStart units are fitted with ventilation grilles to help
disperse any gases produced during the charging procedure.
IMPORTANT: To reduce the risk of a battery explosion, follow these instructions and those published by the battery manufacturer
and the manufacturer of any equipment you intend to use in the vicinity of the battery. Remember to review warning marks on all
products and on engines. Modern vehicles contain extensive electronic systems. Check with the vehicle manufacturer for
any specific instructions regarding the use of this type of equipment on each vehicle. No liability will be accepted for damage/injury
where this product is not used in accordance with all instructions.
1.1.
PERSONAL PRECAUTIONS

Ensure there is another person within hearing range, or close enough to come to your aid should a problem arise, when working
near a lead-acid battery.

Have fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.

Wear safety eye protection and protective clothing. Avoid touching eyes while working with a battery.
Wash immediately with soap and water if battery acid contacts skin or clothing. If acid enters eye, flush eye immediately with cool,

clean running water for at least 15 minutes and seek immediate medical attention.

Remove personal metallic items such as rings, bracelets, necklaces and watches. A lead-acid battery can produce a short-circuit
current high enough to weld a ring or the like to metal, which may cause severe burns.
1.2.
IMPORTANT SAFETY INSTRUCTIONS

Familiarise yourself with the applications, limitations and potential hazards of the RoadStart.

Keep the unit in good working order and condition. Replace damaged parts immediately.

Use only recommended parts. To use unapproved parts may be dangerous and will invalidate your warranty.
The RoadStart must only be opened and checked by qualified service personnel. DO NOT disassemble the unit for any reason.


Keep children and unauthorised persons away from the work area.

Keep work area clean and tidy and free from unrelated materials. Ensure that there is adequate lighting.
If the RoadStart receives a sharp knock or blow, it must be checked by a qualified service agent before being used.


When not in use re-charge every two months.
DO NOT smoke or allow a spark or flame in the vicinity of the battery or engine.


DO NOT drop any metal item onto the battery as it may spark or short circuit the battery, which could cause an explosion.

DO NOT use RoadStart to recharge dry cell batteries that are commonly used with home appliances. These batteries may explode
and cause personal injury and damage to property.

DO NOT charge or boost a frozen battery.

DO NOT use attachments other than those recommended. To do so may risk damage to the unit and other equipment and possible
personal injury.

DO NOT pull or carry the unit by its cables and DO NOT pull the negative and positive clamps from the battery terminals.
DO NOT operate in vicinity of flammable liquids or gases.


DO NOT recharge the unit with plugs, cables or attachments that are damaged. Replace such items immediately.
© Jack Sealey Limited
ROADSTART® EMERGENCY POWER PACK
12V 900 PEAK AMPS
MODEL NO:
Wear eye
Warning:
protection
Corrosive
substance
Original Language Version
RS131.V6
Wear
Electrical
protective
shock hazard
gloves
Use in well
Keep in dry
ventilated
area. Protect
areas
from rain
RS131.V6
Issue: 1 - 11/10/18
Keep away
from sources
of ignition

Advertisement

loading

Summary of Contents for Sealey ROADSTART RS131.V6

  • Page 1 RS131.V6 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and maintained properly, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    RCD with portable products that plug into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You can obtain a Residual Current Device through your Sealey stockist. You must read and understand instructions concerning electrical safety.
  • Page 3: Operation

    12V Power sockets The PowerStart is fitted with 2 x 12V power sockets (fig.1.4). They will each accommodate a male 12V accessory plug up to a combined total of 15A. RS131.V6 Issue: 1 - 11/10/18 Original Language Version © Jack Sealey Limited...
  • Page 4: Battery Removal

    No. All jump starting instructions must be proof? followed carefully. Can I replace the Yes, but note that the batteries are not internal batteries? covered by warranty as they are consumable items RS131.V6 Issue: 1 - 11/10/18 Original Language Version © Jack Sealey Limited...
  • Page 5 BATTERY REMOVAL - SEE SECTION 7 Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.