Connecting Peripheral Equipment To The Ccu - Bosch Digital Congress Network Installation And Operating Manual

Hide thumbs Also See for Digital Congress Network:
Table of Contents

Advertisement

Digital Congress Network | Installation and Operating Manual | Chapter 4 - Central Control Equipment
4.8

Connecting peripheral equipment to the CCU

The Central Control Unit can connect to the following external equipment:
Recording equipment (Recording floor only)
Public address system
Telephone coupler
Mixing desk
The interconnection facilities located at the rear of the unit
In
1. Two Cinch-type sockets, Input (
) and Output (
(Rec.).
2. Two cinch-type sockets for Asymmetrical line Input (
3. Two cinch-type sockets for Symmetrical/Asymmetrical line Output (
Rec.
Line
Port 1
In
Port 2
Out
Symmetrical
Rec.
Line
In
1
Out
Symmetrical
3
FIG 4-7 Connecting peripheral equipment
Bosch Security Systems | 04-2003 | 3922 988 43318 en
(FIG
4-7) are as follows:
Out
) for connection to a tape/cassette recorder
In
).
Out
).
Trunk
In
Out
2
Cinch socket
Signal +
In
Out
Screen
Get other manuals https://www.bkmanuals.com
This section of the page has been left blank intentionally
en | 4-11
Connecting peripheral equipment to the CCU
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents