X32, Mains Contactor Control and DC Bus Short Circuit

Function, Pin Assignment
Data
Contact resistance at minimum
load
Number of mechanical switching
cycles
Fig.5-14:
Technical Properties
For the application prototypes of the supply units, the "WARN"
contact had been realized as N/O contact. From the following
hardware indices (HWIs) upwards, the "WARN" contact is realiz‐
ed as N/C contact:
HMV01.1E-W0030: From HWI -14 upwards
HMV01.1E-W0075: From HWI -14 upwards
HMV01.1E-W0120: From HWI -15 upwards
HMV01.1R-W0018: From HWI -17 upwards
HMV01.1R-W0045: From HWI -17 upwards
HMV01.1R-W0065: From HWI -18 upwards
View
Fig.5-15:
View
Is used to connect the signals for controlling
the mains contactor
the ZKS stage (ZKS = DC bus short circuit)
the braking resistor switch-on threshold
DOK-INDRV*-HMV01******-IT01-EN-P
Rexroth IndraDrive Supply Units HMV01
Unit
Min.
Typ.
mOhm
10
Max.
6