Siemens SIMATIC IPC227G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC227G:
Table of Contents

Advertisement

Quick Links

SIMATIC IPC227G
SIMATIC
Industrial PC
SIMATIC IPC227G
Operating Instructions
07/2022
A5E50059933-AC
Preface
Overview
Safety instructions
Installing and connecting
the device
Commissioning the device
and device functions
Expanding and assigning
parameters to the device
Maintaining and repairing
the device
Technical specifications
Technical support
SIMATIC IPC227G with AI
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
A
B
C
D

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC227G

  • Page 1 Industrial PC SIMATIC IPC227G Commissioning the device and device functions Expanding and assigning parameters to the device Operating Instructions Maintaining and repairing the device Technical specifications Technical support SIMATIC IPC227G with AI Markings and symbols List of abbreviations 07/2022 A5E50059933-AC...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    USB stick in PDF format (in multiple languages). Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC227G in this documentation. Instead of the specific names of the operating system, we are using the abbreviation "Windows 10"...
  • Page 4 The following editions of these operating instructions have been published: Edition Comment 06/2021 First edition 09/2021 Add the UL HAZ. LOC. certification and ATEX information 07/2022 Add PLP SSD configuration and Coral AI Accelerator card information SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 5: Table Of Contents

    Installing the cable strain relief................... 33 3.3.7 Installing Ethernet connector strain relief ................34 3.3.8 Installing the ATEX cable strain relief .................. 36 Commissioning the device and device functions ................37 General information on commissioning ................37 SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 6 USB 3.1 port ........................77 7.5.2.3 DC in connector ......................... 78 7.5.2.4 Ethernet port ........................78 7.5.2.5 DisplayPort ........................79 7.5.2.6 Serial interface ........................79 7.5.3 Internal interfaces ......................81 7.5.3.1 Overview of internal interfaces ..................81 SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 7 Technical support ..........................91 Service and support ......................91 Troubleshooting ........................ 92 Notes on the use of third-party modules ................93 SIMATIC IPC227G with AI ........................95 Markings and symbols ......................... 97 Overview ........................... 97 Safety ..........................97 Operator controls....................... 97 Certificates, approvals and markings ..................
  • Page 8 Table of contents SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 9: Overview

    Overview Product description 1.1.1 Overview SIMATIC IPC227G provides high-level industrial functionality: • Compact design • Scalability • High degree of ruggedness • Various interfaces • Maintenance-free operation possibility 1.1.2 Configuration plan Mounting The device supports the following three mounting types: •...
  • Page 10 • Support 2 × M.2 Module on the motherboard Coral AI Accelerator card • Support 1 × AI Accelerator card For detailed information, refer to SIMATIC IPC227G with AI (Page 95). Interfaces Ethernet • 3 × RJ45 Ethernet 10/100/1000 Mbps COM (optional) •...
  • Page 11: Structure Of The Devices

    The front view on the left is the standard mounting position. The side view is on the right. ① Cooling fins ② LED display Bottom view ① Protective conductor connection ② M.2 SSD slot ③ Interfaces SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 12: Interfaces Of The Device

    Flashing green/yellow (1 Hz) BIOS in POST, power switch on Orange During the S4/S5 state Flashing red (1 Hz) Watchdog status display: active RUN/STOP / L1 Green Can be controlled by user program/control program (e.g. software controller) SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 13: Accessories

    Customer Support page of Siemens Industry Automation and Drive Technologies. (https://support.industry.siemens.com/cs/us/en/) Accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Additional accessories can be found on the Internet: •...
  • Page 14 Overview 1.3 Accessories Dust protection set The Dust protection set interfaces contains: • 40 pieces covers for USB interface • 20 pieces covers for RJ45 Ethernet connection • 10 pieces DisplayPort cover SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 15: Safety Instructions

    The installation of expansions can damage the device, machine or plant. Device and system expansions can violate safety rules and regulations regarding radio interference suppression. If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 16 • Replace the lithium battery only with an identical battery or types recommended by SIEMENS (article number: A5E48370874). • For any requirements on product maintenance, contact Siemens Technical support (Page 91). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 17: Security Information

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 18: Data Protection

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 19: Installing And Connecting The Device

    A damaged packaging indicates that ambient conditions have already had an impact on the device. The device might be damaged. Do not dispose of the original packaging. Pack the device during transportation and storage. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 20: Identification Data Of The Device

    The device can be clearly identified with the help of this identification data in case of repairs or theft. Enter the identification data in the following table: Identification data Source Value Serial number Product label S VP ... Order number Product label 6ES7647-8C... Production version Product label SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 21 Ethernet address 2 (MAC) Ethernet address 3 (MAC) Product label The following image shows the product label on the SIMATIC IPC227G as an example. COA label Microsoft Windows "Product Key" on the "Certificate Of Authenticity" (COA): The COA label is only attached to the rear of the device containing a preinstalled and activated Windows operating system.
  • Page 22: Permitted Mounting Positions

    • Underneath of the device at least 100 mm • Side and above of the device at least 50 mm • The ambient reference point is 40 mm distance from the left side of the device during Hazardous Locations testing. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 23: Mounting The Device

    • This device is designed for use in a normal industrial environment. Without additional protective measures (such as the provision of clean air), SIMATIC Box PCs may not be operated in harsh environments that are subject to caustic vapors or gases. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 24 The position of the interface side is determined by the mounting of the mounting bracket. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 25 This can result in personal injuries or material damage. Ensure that the wall is capable of bearing four times the total weight of the device (including the brackets and expansion modules). The total weight of the device is approximately 2 kg. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 26: Mounting On A Standard Rail

    Mounting on a standard rail Mounting on a standard rail is suitable for horizontal and vertical mounting of the device. Requirement • A SIEMENS 35 mm standard rail TH35-15 conforming to EN 60715:2001 The standard rail is mounted. • A standard rail bracket The standard rail bracket and two screws are included in the order variant "Standard rail...
  • Page 27: Wall Mounting

    Requirement • Two mounting brackets The mounting brackets and four screws are included in the order variant "Upright mounting". • A T10 screwdriver • Four anchors and four screws SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 28: Connecting The Device

    • Always pull out the power plug when you are not using the device or if the device is defective. The power plug must be freely accessible. • Use a central power isolating switch for cabinet installation. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 29 Utilisez des câbles en cuivre (Cu) pour tous les câbles d'alimentation qui sont raccordés à l'appareil par des bornes, par exemple les câbles d'alimentation 24 V CC sur le connecteur d'alimentation 24 V CC. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 30: Connecting The Protective Conductor

    Firmly attach the cable lug to the protective conductor connection on the device using the M4 thread (see part labeled). Connect the protective conductor to the protective conductor connection of the cabinet or the plant in which the device is installed. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 31: Connecting The Power Supply

    – rated temperature 75 °C • Tightening torque: 0.56 Nm • A slotted screwdriver with approximate 3 mm blade. Procedure Switch off the 24 V DC power supply. Connect the wires of the power supply. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 32: Securing Cables

    Make sure that the cables are not crushed by the cable ties. Secure the cable strain relief plate to the device using the supplied screws. The following figure shows an example of the fixing elements of a built-in device. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 33: Connect Device To Networks

    You can find additional information in Technical support. (Page 91) 3.3.6 Installing the cable strain relief The cable strain relief plate carries the cables and prevents unintentional loosening of the connector from the device. The cable strain relief is available as an accessory. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 34: Installing Ethernet Connector Strain Relief

    The Ethernet connector strain relief prevents accidental loosening of the Ethernet connector from the device. The Ethernet connector strain relief is available as an accessory. Procedure Unscrew the marked retaining screw. Insert the metal plate of the Ethernet connector strain relief into the second groove. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 35 M3 × 8 panhead screw from the accessory. Fasten the Ethernet connector strain relief with two M3 × 6 setscrews on the right side. Secure the Ethernet connector with cable ties for each port. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 36: Installing The Atex Cable Strain Relief

    Secure the strain relief with an M3 × 6 setscrew on the left and right sides respectively. Secure the connection cables with cable ties to the cable strain relief. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 37: Commissioning The Device And Device Functions

    • The protective conductor is connected. • The connection cables are plugged in correctly. • The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse – A monitor/display SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 38: Switching The Device On/Off

    If the device is not going to be used for a long period of time after shutdown, set the On/Off switch to "OFF" position. Additional information Information on your operating system can be found on the Internet: • Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/en/view/109749498) SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 39: Advanced Device Functions

    • Temperature nearby the processor A temperature error is triggered when one of the three temperature values exceeds the set temperature threshold and the following reaction is initiated: Reaction Option The DiagBase or DiagMonitor software is enabled None SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 40: Watchdog (Wd)

    The "Reset on" option immediately triggers a hardware reset that can cause data loss on Windows and damage to the installation. Watchdog monitoring times The hardware supports the following control unit times: • 1 to 256 seconds • 1 to 256 minutes SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 41: Battery Monitoring

    A memory window with a maximum size of 512 KB can be displayed by means of PCI address register. The base address is initialized via the BIOS (see section "Input/output address areas (Page 84)"). A corresponding function is implemented there for using the NVRAM under software controller. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 42 Commissioning the device and device functions 4.3 Advanced device functions SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 43: Expanding And Assigning Parameters To The Device

    Remove the marked four screws on the rear panel of the device. Lift up the device's rear panel. Procedure - closing the device To close the device, carry out the steps for opening the device in the reverse order. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 44: Installing The M.2 Module

    Installing the M.2 Module Introduction to the M.2 Module Siemens uses the M.2 Module to extend the Siemens IPC. It can be produced by Siemens or other third-party suppliers. Our device provides one or several M.2 Key B interfaces and mounting positions.
  • Page 45 : You can through the SIM card slot to install the 4G/5G SIM card to connect to the network. But SIM card function has not been certified in both ordinary location and hazardous location. Requirement • The device is opened. • A T8 screwdriver SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 46 If the M.2 Module has a cable with an additional interface-card connect to the housing opening, you need to do the following procedures: Unscrew the marked screws for fixing the COM interface. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 47: Installing And Removing M.2 Nvme/ Sata Ssd

    The device has a slot for M.2 NVMe or SATA SSD on the side of the interface panel. Requirement • The device is disconnected from the power supply. • A M.2 NVMe/SATA SSD that is approved for industrial applications. • A T10 screwdriver SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 48 Plug in the slot back into the device and tighten it with designated screws. Procedure - removing the M.2 NVMe/SATA SSD To remove the M.2 NVMe/SATA SSD, carry out the steps for installing the M.2 NVMe/SATA SSD in the reverse order. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 49: Maintaining And Repairing The Device

    Maintaining and repairing the device Maintenance intervals To maintain high system availability, Siemens recommends you replace some of the PC components that subject to wear in according with the replacement intervals indicated in the table below. Component Replacement interval: CMOS backup battery...
  • Page 50 • T20 screwdriver for protective conductor connection • T8 screwdriver for spring screw and M.2 Module on the motherboard • T10 screwdriver for all the remaining screws SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 51: Installing And Removing Hardware

    – Rated voltage: 3 VDC – Max abnormal charging current: 10 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 91). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 52 – Courant de charge anormal max. : 10 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 91) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
  • Page 53: Replacing The Memory Module

    DDR4 up to 3200MT/S SODIMM 260pin Requirement • The device is disconnected from the power supply. • All connecting cables on the device are unplugged. • The device is opened. • T8, T10 and T20 screwdrivers SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 54 ESD directives on handling electrostatic sensitive components. Note Siemens strongly recommends that you use only memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules. To replace the memory module CAUTION •...
  • Page 55: Reinstalling The Operating System

    Pull out the memory module from the socket. Reinstalling the operating system Information on installation of the operating system is available on the Internet: • Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/en/view/109749498) SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 56: Installing The Drivers And Software

    Step 1: install the chipset driver 1. Click Step1: Intel® Chipset Device Software. 2. Click to install the chipset driver. 3. Click Next to continue. 4. Click Accept to accept the license agreement. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 57 1. Click Step4: Intel® Gigabit Ethernet Driver. 2. Click to install the Gigabit Ethernet driver. 3. Click Yes to confirm the user account control question. 4. Click Next to continue. 5. Click Finish. The installation is completed. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 58: Recycling And Disposal

    Recycling and disposal Due to their low level of pollutants, the devices described in these operating instructions can be recycled. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 59: Technical Specifications

    The following shows the approvals that may be available. For the device itself, it is certificated as shown on the product label and package label. ISO 9001 certificate The Siemens quality management system for all production processes (Development, Production, Sales and Service of Automation Products, -Systems and -Solutions) meets the requirements of ISO 9001:2015 This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 60 Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Responsible party for Supplier's Declaration of Conformity Siemens Industry, Inc. Digital Factory - Factory Automation 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 Mail to: (amps.automation@siemens.com)
  • Page 61 铅 Lead 汞 Mercury 鎘 Cadmium 六價鉻 多溴聯苯 多溴二苯醚 Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) chromium(Cr biphenyls(PBB) diphenyl ethers (PBDE) 外殼 ○ ○ ○ ○ ○ ○ 電路板 ○ ○ ○ ○ ○ ○ SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 62 • The equipment is acceptable for use in different ambient temperature ranges (Ta: ˚0C to 45˚C/50˚C/55˚C) depending on CPU types, mounting positions and NVRAM availability. Users shall access Operating Instructions (document no. A5E50059933-AB) Ambient Conditions section for details. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 63 DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". cULus HAZ. LOC. approval in file No.E472610...
  • Page 64 You can find certificates on explosion protection, EC/EU declarations of conformity, product approvals and other certifications on the Internet at the following addresses: • Device certificates (https://support.industry.siemens.com/cs/ww/en/ps/28295/cert) For the device with "Ex" marking, the following approvals apply according to the following standards.
  • Page 65: Directives And Declarations

    Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 58) ". Directives and declarations 7.2.1 Electromagnetic compatibility, Industrial and Residential Areas Electromagnetic compatibility This product meets the requirements of EC Directive 2014/30/EU "Electromagnetic Compatibility". SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 66: Rohs Directive

    The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 67 There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 68: Dimension Drawings

    – Discharge your body electrostatically by touching grounded metallic parts before you take a measurement at a module. Always use grounded measuring instruments. Dimension drawings Mounting on a standard rail all dimensions in mm SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 69 Technical specifications 7.3 Dimension drawings Wall mounting all dimensions in mm SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 70 Technical specifications 7.3 Dimension drawings Upright mounting all dimensions in mm SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 71: Technical Data

    ± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4; conducted interference on the Burst supply lines • ± 1kV line to line, ±2 kV line to earth in accordance with IEC 61000-4-5; Surge SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 72 4G DDR4 SDRAM • 8G DDR4 SDRAM • 16G DDR4 SDRAM The max speed of memory is up to 3200 MT/s. The memory module supports IBECC function, and its default value in BIOS is "Disable". SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 73 You can find additional information in the section "Power demand of the components (Page 75)". Connection of a DP monitor Keyboard, mouse Connection via USB port In BIOS Setup, you can configure support for RS232/RS422/RS485 for COM1 and COM2 ports. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 74: Ambient Conditions

    : Atmospheric pressure and air density increases with decreasing altitude. Therefore utilization of the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative. The altitude of operation is maximum 2000 m for Hazardous Locations applications. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 75: Power Demand Of The Components

    Per slot 1.5 A X101) Note Device may overheat! The power supply cannot make unlimited power available. The auxiliary components consume energy and produce heat. The device may overheat. The auxiliary components will be damaged. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 76: Direct Current Supply (Dc)

    Device with Intel Atom® x6211E 14 W Device with Intel Atom® x6413E 18 W Device with Intel Atom® x6414RE 17 W USB expansion See section "Power demand of the components (Page 75)" M.2 Module SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 77: Hardware Descriptions

    2 × DP++ External 9-pin D-sub, either: • 2 × RS232/RS485/RS422 7.5.2.2 USB 3.1 port Short name Meaning Input / output VBUS + 5 V (Power switch) Power out Data channel USB2 Input / output SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 78: Dc In Connector

    Input/output Shield – LED 1 Orange light:1000 Mbps – Off: else LED 2 Orange light: Link – Orange Blink: Activity Off: No Link The Ethernet interface supports MDXI (auto crossover) for all transmission rates. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 79: Displayport

    DP data 3- Output CONFIG1 CONFIG1 CONFIG2 CONFIG2 AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3 V (Power switch) power out 7.5.2.6 Serial interface RS232 RS422 RS485 SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 80 Receive data - (I) for full-duplex mode Signal ground Pin assignment RS485 Short description Meaning Data- Transmit / receive data - (I/O) for half-duplex mode Data+ Transmit / receive data+ (I/O) for half-duplex mode Signal ground SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 81: Internal Interfaces

    RESET# SIM DETECT ANTCTL3 COEX_RXD(I) ANTCTL2 COEX_TXD(O) ANTCTL1 COEX3(I/O) ANTCTL0 REFCLKp PEWAKE# REFCLKn CLKREQ# PERST# PETp0 PETn0 ALERT# PERp0 SMB_DATA PERn0 SMB_CLK DEVSLP PETp1 UIM-PWR PETn1 UIM-DATA UIM-CLK PERp1 UIM-RESET PERn1 CONNECTOR KEY B SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 82 COEX3(I/O) PERp0 SMB_DATA PERn0 SMB_CLK DEVSLP PETp1 PETn1 PERp1 PERn1 CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 83: Usb 2.0 Pin Header

    1. Right-click the Windows Start menu and select "Device Manager". 2. Click on the View menu and turn on " Resources by type" or "Resources by connection". All the interrupts show under the Interrupt request (IRQ) catalog. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 84: Input/Output Address Areas

    SIO logic device 7 CR E9h Control register user LED L1/L2/L3 (Page 85) SIO logic device 7 CR FDh Battery status register (Page 85) For more information and reference code for accessing to Super IO, contact Siemens Technical support. 7.5.5.2 Watchdog control register...
  • Page 85: Watchdog State Register

    LED L3 lit red LED L3 lit green LED L3 lit orange 7.5.5.6 Battery status register The status of the CMOS battery is monitored; the status (two-tier) can be read from the battery status register. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 86: Nvram Address Register

    The BIOS Setup program, or BIOS Setup for short, is located, together with the setup parameters, in a FLASH block on the motherboard. Change the setup parameters of the device in the BIOS Setup, e.g. system time or boot sequence. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 87: Bios Update

    Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/109797240). 7.6.2 BIOS update Check regularly if updates are available for download to your device. You can find additional information on the Internet at the following address: After-sales information system for SIMATIC PC/PG (http://www.siemens.com/asis). SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 88 If you have purchased a new BIOS update for your device, follow these steps to install the update: 1. Connect the device to the power supply. 2. Take the BIOS update you downloaded from the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/75852684)page and place it on the USB stick.
  • Page 89: Alarm, Error And System Messages

    Check the CMOS clock. Keyboard error • Field PG: Internal keyboard defective and no external keyboard connected • Other devices: Keyboard defective or not connected SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 90 Technical specifications 7.6 BIOS description SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 91: Technical Support

    Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 92: Troubleshooting

    You need to install the USB device drivers for the supported. required operating system. The pop-up message The M.2 NVMe/SATA SSD card is Press Enter to continue the boot. "Windows boot manager changed to another boot device. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 93: Notes On The Use Of Third-Party Modules

    If the error no longer occurs, the third-party module • Different pin assignment being used was the cause of the fault. Replace the third-party module with a Siemens module or contact the module supplier. If the device still crashes, contact your technical support team. •...
  • Page 94 Technical support A.3 Notes on the use of third-party modules SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 95: Simatic Ipc227G With Ai

    The information in this product information takes precedence over statements in the basic operating instructions, the release notes and online help. Features • The features of the "SIMATIC IPC227G with AI" differ from the features of the standard device SIMATIC IPC227G as follows: Additional hardware equipment: –...
  • Page 96 SIMATIC IPC227G with AI Information on commissioning Important note By default, the Coral PCIe driver drives the Edge TPU with a maximum frequency of 500 MHz. Under certain circumstances, continuous operation at this frequency can result in overheating. The PCIe driver contains a dynamic frequency scaling that is activated by default.
  • Page 97: Markings And Symbols

    Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical Eject CD/DVD isolation On/off switch, without electrical isolation SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 98: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters Disposal information, observe the Laboratories local regulations. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 99: Interfaces

    DVI-D interface Line In LAN interface, not approved for Line Out connecting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 100 Markings and symbols C.5 Interfaces SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 101: List Of Abbreviations

    Disk Operating System DisplayPort Deutsche Gesellschaft zur Zertifizierung von Qualitätsmanagement mBH Data Set Ready Ready for operation Data Terminal Ready Data terminal is ready Digital Versatile Disk Components sensitive to electrostatic charge European standard SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 102 New Technology File System NVMe Non-Volatile Memory Express NVRAM Non Volatile Random Access Non-volatile data memory. Data memory is Memory retained without external power supply. Optical Disk Drive Personal computer Peripheral Component High-speed expansion bus Interconnect SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 103 Intel technology which provides a virtual, closed environment. VT-d Virtualization Technology for Enables the direct assignment of a device (e.g. Directed I/O network adapter) to a virtual device. Watchdog Program monitoring with error detection and alarming. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 104 List of abbreviations SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 105: Glossary

    Communauté Européene: The CE symbol confirms the conformity of the product with all applicable EC directives such as the EMC Directive. Chipset Located on the motherboard, connects the processor with the PCI or PCIe bus and the external interfaces. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 106 TVs to computers, DVD players and similar devices. Drivers Program parts of the operating system. They adapt user program data to the specific formats required by I/O devices such as hard disk, printers, and monitors. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 107 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 108 Intel Active Management Technology This technology permits diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 109 Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens AG issues a license key for each software that is protected by a license. License key USB flash drive The license key USB flash drive contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 110 Industrial Ethernet meets the requirements of industrial automation technology. Programmable controller The programmable controllers of the SIMATIC S7 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 111 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 112 Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 113: Index

    Interfaces Degree of protection, 71 RJ45 Ethernet, 78 Device USB 3.0, 78 Closing, 43 IT communication, 33 Open, 43 DiagBase software, 39 DiagMonitor Temperature monitoring, 39 Korea Certificate, 61 Diagnostics, 39 DiagBase software, 39 SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 114 USB, 77, 81 Removing, 19 USB 3.0 Pile au lithium, 52 Interface, 78 Power supply DC power supply, 76 Processor, 72 Product label, 21 PROFINET, 33, 76 Wall mounting, 27, 69 Protection class, 71 Warranty, 15 SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...
  • Page 115 Index Watchdog, 40 Monitoring function, 40 Monitoring times, 40 Weight, 71 SIMATIC IPC227G Operating Instructions, 07/2022, A5E50059933-AC...

Table of Contents