8
en | Graphics
mounted horizontally on the ceiling in centered position with
a minimum distance of 0.5m to walls and objects. On slanted
ceilings >20° it is to be mounted 0.5m to 1m from the top of
the ceiling. (2.A), (2.B), (2.C), (2.D)
2. For each device: Mounting the base. (5) Observe the mark
(5.2) for adjusting the emergency light and the marks (5.1)
for alignment with BOSCH label/siren.
3. Functional check, page 9, for each device after setting it up
into operation. (6) (7)
Unsuitable locations for mounting
Kitchen/bathroom (steam)
Rooms with open fireplaces (fumes)
In the immediate vicinity of halogen lamps, transformers,
fluorescent or energy-saving lamps
Garages (exhaust fumes)
Dusty and dirty rooms
In the vicinity of windows, ventilators (air movement)
In the vicinity of areas where people smoke
Audibility
You must hear an alarm at any place in your building or flat. The
alarm really has to wake you up. If necessary adapt the number of
the devices for achieving audibility in your whole building or flat.
Mounting the base
Mount the base with one central screw and plug. (5.A) Or
optionally use two screws and plugs. (5.B) To set the device into
operation you screw the detector head to its base by twisting it
clockwise until it latches. (6)