Page 1
OWNER’S MANUAL Dome Camera Please read this manual carefully before operating your set and retain it for future reference. MODEL LCP2850-AN/AP LCP2850I-AN/AP...
Safety Information Safety Information Warning: Do not install this equipment in a confined CAUTION space such as a bookcase or similar unit. Warning: Wiring methods shall be in accordance with the RISK OF ELECTRIC SHOCK National Electric Code, ANSI/NFPA 70. DO NOT OPEN Warning: This is a class A product.
Safety Information Safety Precautions LG Electronics hereby declares that this/ these product(s) is/are in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC and 2011/65/EU. • Do not attempt to disassemble the camera Contact office for compliance of this...
Page 5
Safety Information About Static Electricity Removal • Consumables Parts having contacts such as the lens-drive motors, Before installing the camera, touch a metal case or other cooling fan built inside the camera are subject to wear metallic parts with your hand to remove static electricity with time.
Contents Contents Connecting power source Protocol and baud rate settings Camera ID Setting Removing the Protection Tape Mounting the camera Surface mount (optional) Ceiling mount (optional) Safety Information Wall mount (optional) Pendant mount (Optional) Safety Precautions Operation Preparation Setup Menu Overview Introduction Menu navigation Accessing the camera setup menu...
Page 7
Contents Auto Pan setting Privacy Mask setting Special setting OSD Settings User title setting ZOOM MAG setting FUNCTION setting DOME ID setting LANGUAGE Setting ALARM Setting Alarm In setting Alarm Out setting RESET Setting Information Initialization Camera reset Factory reset Appendix Specifications...
Preparation Preparation Introduction reproduced repeatedly. The Pan, Tilt and Zoom controls are available for pattern recording. Note The available total time of pattern differs depending The dome cameras are designed for installation in an on camera’s operation. When the pattern recording is indoor or outdoor video surveillance system.
The camera can be best condition to watch easily inside or outside in the strong back light. • Power Supply This camera must always be operated a AC 24 V. PIPE Installation Bracket Certified/Listed Adaptor which comply with LPS. Accessories For LCP2850I-AN/AP RJ-45 Adapter cable Camera mounting bracket...
Preparation Part Names and Functions BNC connector cover cap Video output BNC connector LCP2850I-AN/AP for Indoor Supplies analog video signal (composite) to the connected device. Data Port A (RJ-45) RS-485 data communication and input data port for alarm (relay) signal.
Page 11
Preparation LCP2850-AN/AP for Outdoor BNC connector cover cap Video output BNC connector Supplies analog video signal (composite) to the connected device. RS-485 Data Communication Alarm In Data Terminal Input data terminal for alarm (relay) signal. Alarm Out Data Terminal Output data terminal for alarm (relay) signal. Power input Terminal Connects to a AC 24 V power supply using proper cables.
Before you install and connect the camera, check and prepare the required peripheral devices and cables. • Before you connect the camera, turn off all devices to be connected, such as this camera and DVR. • Do not touch the dome cover’s window. Basic Connection Overview LCP2850I-AN/AP (for Indoor) LCP2850-AN/AP (for outdoor)
NO (normally open) or NC Black (normally closed) through the setup menu. ALARM IN COM For LCP2850I-AN/AP ALARM IN 1 Green 1. Connect the RJ-45 Adaptor cable to the PORT A (RJ-45) ALARM IN 2 Yellow cable of the camera.
Page 14
Installation PORT A Alarm input connection Description Color RS-485 + Red/White RS-485 - Black/White ALARM IN COM Alarm device ALARM IN 1 White Alarm device ALARM IN 2 Light Green ALARM IN 3 Yellow Alarm device ALARM IN 4 Pink Alarm device For LCP2850-AN/AP 1.
Alarm signal output at an event occurrence. You can set the Alarm Output to the normal open or normal close mode. Alarm Input function For LCP2850I-AN/AP This speed dome camera has a terminal that can sense the 1. Connect the RJ-45 Adaptor cable to the PORT B (RJ-45) alarm signals.
Page 16
Installation For LCP2850-AN/AP ALARM OUT [NO2] Green 1. Connect the Adaptor cable to the Alarm Out Data Terminal of the camera. ALARM OUT [COM2] Yellow 2. Connect the alarm device to the Adaptor cable. ALARM OUT [NC2] Blue When connecting lines, check and connect the color lines of the each device correctly.
Orange more details.) LKD1000 connection Connecting LKD1000 controller For LCP2850I-AN/AP 1. Connect the RJ-45 Adaptor cable to the PORT A (RJ-45) cable of the camera. 2. Connect the LKD1000 controller to the RJ-45 Adaptor cable. (Refer to the manuals of the LKD1000 controller for more details.)
Page 18
Installation RJ-45 Adapter cable PORT A For LCP2850I-AN/AP For LCP2850-AN/AP RS-485 connection RS-485 connection RS-485 device RS-485 device RS-485 device RS-485 device RS-485 Data Adaptor cable Communication RJ-45 Adapter cable RJ-45 Adapter cable PORT A PORT A 1. Connect the adaptor cable to the RS-485 Data 1.
Pelco D Pelco P OSD Set Note If you are not using the controller with LG Multix protocol, there may be some limitation of function control. 5. Assemble the dome cover and the camera assembly cover in the reverse order.
Installation Camera ID Setting OFF OFF OFF OFF OFF The camera’s ID is set to “0” as factory default. If you use OFF OFF OFF two or more cameras simultaneously, change the ID of the OFF OFF OFF cameras. OFF OFF OFF Set the camera ID setting referring to the pictures and the table on the below.
Page 21
Installation OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF...
Page 22
Installation OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF...
OFF OFF 2. Remove the protection tape and attach the dome OFF OFF cover. OFF OFF For LCP2850I-AN/AP models. OFF OFF OFF 1. Press the Dome Cover open button and then OFF OFF disassemble the dome cover by using ALIGN mark.
Installation Mounting the camera 2. Install the surface mounting bracket on the ceiling. You can mount the camera on the ceiling or wall. Surface mount (optional) Follow the instructions below to surface mount the camera. > Caution The building structure must be able to support 8 kg. 1.
Installation Ceiling mount (optional) 4. Tighten the locking screw. Follow the instructions below to mount the camera on the ceiling. > Caution The building structure must be able to support 8 kg. 1. Make a hole through the ceiling as shown below. Ø...
Page 26
Installation 3. Install the ceiling mounting bracket on the ceiling. Face 5. Pass the connection cable through the inner side of the front of the ceiling mounting bracket toward the the ceiling. Connect the cables to the cable jacks of the area of interest.
Installation Wall mount (optional) 7. Tighten the locking screw. Install the camera by the following order. 1. Disassemble the PIPE Installation Bracket to remove the [A] part. 8. Connect the cables to the cable jacks of the cam era 2. Install the PIPE Installation Bracket to the Wall Mount body.
Page 28
Installation 3. Drill a hole on the wall where you want to install the 6. Attach the camera to the camera assembly bracket by pipe. Pass the connection cable through the wall following step a and b. Align the locking point of mount assembly so that they hang down.
2. Install the PIPE Installation Bracket to the Pendant Mount assembly. Note You can install the PIPE Installation Bracket direct to the other type LG Wall Mount assembly. This LG Wall Mount assembly make to easy to install your camera.
Page 30
Installation 3. Drill a hole on the wall where you want to install the 4. Install the pendant mount assembly. pipe. Pass the connection cable through the pendant mount assembly so that they hang down. 5. Connect the connection cable and the safety cable to the camera body.
Page 31
Installation 6. Attach the camera to the camera assembly bracket by 7. Tighten the locking screw. following step a and b. Align the locking point of the wall mount assembly and the camera.
Page 32
Installation Note 8. Assemble the camera cover as shown below. You can install the PIPE Installation Bracket direct to the other type LG Wall Mount assembly. This LG Wall Mount assembly make to easy to install your camera.
Operation Operation Setup Menu Overview The following table shows the list of menu items and options. You can adapt the camera to your requirements by setting up the respective items in these menus. 1st level 2nd level 3rd level Contents CAMERA SET FOCUS FOCUS MODE...
Page 34
Operation CAMERA SET DAY/NIGHT AUTO D/N LEVEL LOW/MIDDLE/HIGH DWELL TIME 5,10,15,30,60 SEC RETURN NIGHT 3D-DNR MIDDLE HIGH COLOR COLOR -50 to 50 SHARPNESS 0 to 68 STABILIZER RETURN PAN/TILT SET PRESET SET PRESET NAME OFF/ON SPEED 1 to 127 DWELL TIME 1 to 255 IRIS AUTO, 20, 40, 60, 80, 100 %...
Page 35
Operation PAN/TILT SET GROUP TOUR SET GROUP 1 to 10 1 to 10 CLEAR 1 to 10 RETURN PATTERN RECORD 1 to 4 1 to 4 RETURN AUTO PAN SET AUTO PAN 1 to 8 CLEAR RETURN PRIVACY MASK MASK NUMBER 1 to 8 SET MASK MASK STATE...
Page 36
Operation PAN/TILT SET SPECIAL COMMUNICATION LG MULTIX/ PELCO C/ PROTOCOL PELCO D/ PELCO P 2 400/ 4 800/ 19 200/ 38 400/ BAUDRATE 9 600 BPS SAVE & EXIT RETURN OSD SET USER TITLE ON/OFF ZOOM MAG ON/OFF FUNCTION ON/OFF...
We use the LKD1000 controller in this manual to explain PRESET /CAM1 the features of the LG Dome camera because of the LKD1000’s ability to control all of the LG Dome camera’s advanced features. (For detailed controller instructions, refer to the LKD1000 Controller Manual.)
Operation Camera menu settings Focus Distance setting Selects the minimum shooting distance for the focus. Select [FOCUS DIST] option on the [FOCUS] menu, then select a focus distance value. Focus setting Zoom Start setting The camera adjusts the focus automatically by sensing the You can set the zoom start position of the camera.
Operation SHUTTER (Shutter Speed) setting • AUTO: The lens iris is set automatically. Select the desired shutter speed for camera exposure. You • MANUAL: Use [Near] or [Far] button to select the DC Iris can change the shutter speed to higher speed to capture level.
Operation When the scene mostly contains high color D/N LEVEL: Use [Near] or [Far] button to select a temperature objects, such as a blue sky or level. sunset. DWELL TIME: Use [Near] or [Far] button to select When the scene is dim. a dwell time.
Operation Color setting Stabilizer setting You can switch the displayed picture to grayscale or color. The image stabilizer function minimizes the appearance of shaky images caused by low-frequency vibration. This function is useful for outdoor surveillance. 1. Select [COLOR] option on the [CAMERA SET] menu. 1.
Page 42
Operation To register preset positions 2. Select the memorized preset position’s index number then press [Open] or [Close] button. The camera moves 1. Select the [SET PRESET] option on the [PRESET] menu. to the preset position and the picture of the camera in 2.
Operation Group tour setting To delete a group You can delete a memorized group. You can create a group using preset positions that are registered already. A maximum of 10 groups is available. 1. Select [CLEAR] option on the [GROUP TOUR] menu. 2.
Operation To play the pattern 8. Repeat steps 1 to 7 to add additional positions. 9. Select [RETURN] option and press [Open] or [Close] 1. Select [RUN] option on the [PATTERN] menu. button to exit the setting menu. 2. Select the recording number and then press [Open] or Note [Close] button to play the programmed pattern.
Operation Special setting 1. Select [PRIVACY MASK] option on the [PAN/TILT MENU]. 2. Press [Open] or [Close] button to display the PRIVACY MASK MENU. 3. Use [Near] or [Far] button to select a zone number on the [MASK NUMBER] option. 4.
Page 46
Operation Home position 2. Use [Near] or [Far] button to set it [ON]. If you do not want to use this function, set it to [OFF]. The home position is the camera’s basic position. The camera returns to this position whenever you want. Note Use the following procedure to make the home position.
Operation OSD Settings • CLR: If you enter the wrong code, select [CLR] then press [Open] or [Close]. All letters will be erased at once. • POS: Move the USER TITLE position on the screen using the [Near] or [Far] buttons. •...
Operation ALARM Setting DOME ID setting Displays or removes the Camera ID OSD on the screen. This camera has a terminal that can sense the alarm signals. The camera can be programmed to go to a preset with a signal from any connected alarm device. 1.
Operation Alarm Out setting Initialization 1. Select one of the alarm out options on the [ALARM You can initialize the camera settings. SET] menu. 1. Select [INITIALIZATION] option on the [RESET] menu. 2. Use [Near] or [Far] button to set it [ON]. 2.
Appendix Appendix Specifications Model LCP2850-AN LCP2850-AP LCP2850I-AN LCP2850I-AP Signal System NTSC NTSC Image Sensor 4.5 mm(1/4 Type) Super HAD II CCD Total Pixels Number 520 000 Pixels 610 000 Pixels 520 000 Pixels 610 000 Pixels Effective Pixels Number 490 000 Pixels...
Page 51
Maximum 10 Groups Coax : Pelco-C (Coaxitron) Protocol RS-485 : LG Multix, Pelco(D/P) Operating Temperature/Humidity -20 ˚C to 50 ˚C / 0 % RH to 80 % RH -10 ˚C to 50 ˚C / 0 % RH to 80 % RH Safekeeping Temperature/Humidity -30 ˚C to 60 ˚C / 0 % RH to 90 % RH...