HP 654 A Series Operating Manual page 18

Analog programmable dc power supplies
Hide thumbs Also See for 654 A Series:
Table of Contents

Advertisement

Table 1-2 b. Supplemental Characteristics for Series 657xA (Note 1)
Parameter
HP 6571A
HP 6572A
HP 6573A
HP C574A
HP 6575A
Output Programming Range {
Voltage:
Overvoltage Protection:
Current:
Vlaximum prog
8.190 V
10.0 V
225.23 A
rammable valu
20.475 V
24.0 V
102.37 A
es):
35.831 V
42.0 V
61.43 A
61.425V
72.0 V
35.83 A
122.85 V
144.0 V
18.43 A
Average Resolution
Voltage:
Current:
OV Protection:
2 mV
55 mA
15 mV
5 mV
25 mA
35 mV
10 mV
15 mA
65 mV
15 mV
8.75 mA
100 mV
30 mV
4.5 mA
215 mV
Accuracy (at calibration temp<
Overvoltage Protection;
Analog Programming (VP):
Analog Programming (IP):
Current Monitor (4-IM):
*Factory calibration temp = 25®
rature ±5® C)
200 mV
C
k
500 mV
900 mV
±0.3
%
±7 %
±7 %
1.15 V
3.0 V
Drift Temperature Stability (fo
constant line, load, and ambien
Voltage:
Current:
flowing a 30-m
t temperature
0.02%-|-0.24mV
0.02%-t-69mA
inute warmup,
0.02%-»-.6 mV
0.02%-|-35mA
change in out
0.02%-|-l mV
0.2%-|-20mA
3ut over 8 hou
0.02%-|-1.8 mV
0.2%+lOmA
rs under
0.02%-f3.6 mV
0.2%-f6mA
Temperature Coefficients (Cha
Voltage:
Current:
Voltage Readback:
iCurrent Readback:
Overvoltage Protection:
Analog Programming (VP):
Analog Programming (±IP):
Current Monitor (-|-IM):
ige /®C and 3{
50ppm-|-0.04mV
75ppm-4-25mA
eOppm-l-O.lmV
85ppm-f30mA
200ppm4-l .8mV
60ppm-f-0.1mV
275ppm-f26mA
50ppm-f3 mA
-minute warm
50ppm-f0.2mV
75ppm-i-12mA
60ppm-f0.3mV
85ppm-f 15mA
200ppm-i-5mV
60ppm-|-0.3m V
275ppm-fl4mA
50ppm-b2mA
up)
50ppm-b0.7mV
75ppm+7mA
60ppm-f ImV
SSppm-bOmA
200ppm-b8mV
60ppm-t-0.5mV
275ppm-|-9mA
SOppm-flmA
50ppm+l .2mV
75ppm+4mA
60ppm-|-1.2mV
85ppm-f5mA
200ppm4-13m V
60ppm-f-0.7mV
275ppm-f-5mA
50ppm+0.6mA
50ppni-+-2.4mV
75ppm-f 2mA
60ppm-f3mV
85ppm-f-2.5mA
200ppm-f25mV
60ppm+1.5mV
275ppm-}'3mA
50ppm-i-0.3mA
Maximum Input Power:
3800 VA; 2600 W, 100 W with no load
Maximum AC Line Current Ra
200 Vac nominal:
230 Vac nominal:
tings
19 A rms
19 A rms
Maximum Reverse Bias
Current:
With AC input power applied eind the dc output reverse biased by an external
dc source, the supply will continuously withstand without damage a current
equal to its output current rating.
Remote Sensing Capability
Voltage drop per lead:
load voltage:
Load Regulation
Degradation due to load lea
Degradation due to load lea
Up to 1/2 of rated output voltage
Subtract voltage drop in load leads from specified output voltage rating
d drop in - output:
None
d drop in
+
output:
AmV
(regulation) = 2Vdrop{Vra,inR)/(Vratine + 10 V)
Monotonicity:
Output is monotonic over entire rated voltage, current, and temperature ranee
Auto-Parallel Configuration:
Up to 5 identical units
•Note 1: For Performance Specifications, see Table 1-lb.
1-12
General Information
Series 657xA
Characteristics

Advertisement

Table of Contents
loading