Init; Error Messages - AEG ARE i2.0x LF Manual

Table of Contents

Advertisement

Manual ARE i2.0x LF release V2

2.2.15 INIT

INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
ASCII:
'I'
Output (example): ACK<CR>
Hex:
41
ASCII:
'A'
The following parameters are set:
BD 3
TOR 50
CID 0
CN 0
MD 2
LSTB 01101
LGT 01111

2.2.16 Error messages

Error messages and protocol errors are acknowledged by ARE i2.0x LF using an error code. The format is described below:
<NAK> '#' <error code> <CR>
Example error #02 (wrong parameter)
Hex:
15
ASCII:
<NAK>
The error code is comprised of a two digit ASCII coded number.
The following table displays possible error messages:
Error code
"00"
"02"
Manual ARE i2.0x LF release V2.docx
4E
49
'N'
'I'
43
4B
0D
'C'
'K'
<CR>
LRD 01001
LNRD 10001
LERR 10011
LRT 30
LPA 00000
LED 1
23
30
'#'
'0'
Meaning
Unknown instruction
Wrong parameter
54
0D
'T'
<CR>
32
0D
'2'
<CR>
Version: 13
Page: 15 / 34

Advertisement

Table of Contents
loading

Table of Contents