en | System installation design and planning
4.4.1

Redundant cabling for DCNM-APS2/DCNM-PS2 units

This section describes how to create redundant cabling for DCNM-APS2 / DCNM-PS2 type
units. The maximum number of Ethernet devices in the largest possible loop (including the
root switch) is 22. In a system with no Ethernet switch(es), the APS is the root switch.
The total number of devices allowed in a loop depends on:
The type of device connected in the loop (for example, DCNM-MMD2 devices consume
more power than DCNM-DE devices).
The length of the loop (cable also consumes power).
The figure shows how to calculate the number of devices in the loop. The grey line shows the
largest loop. The # sign shows the way the devices are counted.
In the example below up to 19 (22 - 3 = 19) discussion devices can be connected.
Figure 4.8: DICENTIS discussion devices connected with redundant cabling between DCNM-PS2 / DCNM-
APS2 type units
1 DICENTIS system
3 DCNM-APS2
5 DICENTIS cabling (redundant loop)
Maximum number of DICENTIS devices in a string:
The max age timer should be set to 22 when RSTP is used for cable redundancy to
prevent a defective cable or powering switch from influencing the system.
Each time data hops from one switch to another, the age is increased by one. This timer
can be reached or exceeded, because a daisy chain can be used to loop through the
DICENTIS devices.
This timer (or restriction) cannot be reached when there is no cable redundancy. This is
because the power limitation will be reached before the max age restriction is reached.
The timer can be reached when:
2023-02 (draft) | 4.3-draft |
1
you use cable redundancy,
the system is incorrectly wired.
Installation manual
2
#1
2 Network switch (with optional
redundant power supply)
4 DCNM-PS2
Bosch Security Systems B.V.