Final Inspection; Product Identification - KitchenAid KP Manual

6-quart solid state stand mixer
Table of Contents

Advertisement

B Fi
o
KitchenAid
6-Quart Stand
Mixer Manual
LIT4176981
©
2002 KitchenAid
BOWL SUPPORT and COLUMN - If service is
needed on the Bowl Support and Column the Lower
Cover should be removed from the Column.
The Motor will have to be removed to gain access
to the (3) 8-32 x 5/8" Phillips Screws that hold the
Lower Gearcase to the Column.
mE
Also remove the Base from the Column and Bowl
Support Assembly.
This is accomplished by removing the (3) 1/4 -20 x
3/4" Phillips Screws from the bottom of the Base.
Remove the lower "C" Clip and the Bow! Support
can now be removed. Later models may use a lock nut
instead of a clip.
STAND MIXER BASE, BOWL SUPPORT
AND COLUMN
a LIFT ARM
DRIVE PIN or
|
"C" CLIP ——
/ / SCREW
sow. EIU
LIFT
ROD
a Ses
LIFT
,
SPRING
HANDLE
WASHER
"C" CLIP or
LOCK NUT
BOWL
SUPPORT
COLUMN
_ ASSEMBLY
LATCH
SPRING
REASSEMBLY - Slide the Bowl Support onto the
Column and allign the Bowl Lift Rod through the hole
on the inside of the Bowl Support.
Position the Bowl Lift Handle so that the Bowl Lift
Rod is extended fully through the hole of the Bowl
Support.
Set the Spring on the Bowl Lift Rod, followed by the
Washer. Using Pliers, lock the "C" Clip to the end of the
Bowl Lift Rod.
Always
rotate the Bowl
Lift Handle
to test the
operation of the Bowl Lift Arm.
KP - KT - KD
6-Quart Stand Mixer Manual - LIT4176981
œ
PEDESTAL
- The rubber feet imbedded
in the
Pedestal should always be checked to insure that the
Mixer has a solid foundation with the work surface.
REPLACING
BOWL
AND LIFT ARM - Remove
the upper "C" Clip, then slide the Bowl Lift Rod out of
the Bowl Lift Arm.
Remove the Pin (Screw on later models).
Pull Bowl
Lift Handle out until tha Arm
can
be
removed.
Reverse Assembly steps to reassemble the Bowl
Lift Mechanism.
FINAL
INSPECTION
- Before repackaging the
Stand Mixer after a Bowl Support and Pedestal Repair
check the foilowing:
* Confirm that Base, Bowl Support and Column
Assembly are soil free. Pay particular attention to the
(5) Rubber Feet imbedded in the base clean if neces-
sary with a mild soap solution.
* Checkthe tightness of ali Phillips Screws used to
fasten the Column to the Base and to the Lower Gear
case. Retighten if necessary.
NOTE: 1/4" Screws are used to attach the Base to
the Column. Use a LARGE Phillips Screwdriver.
e Confirm that both "C" Clips (or Lock Nuts) are
seated properly and are in good condition.
e Confirm the movement of the Bowl Support by
lifting the Bowl Lift Handle.
PRODUCT
IDENTIFICATION
- The Model and
Serial Number Identification Tag are located at the
bottom of the Stand Mixer Base.
This information should always be recorded by the
repair technicían for future reference.
l
Page 8