Electrical Adjustments (Recorder Section); Undercut Adjustment; Atf Bias Adjustment; Avsv Adjustment - Canon Canovision8 E50E Service Manual

8mm video camera & recorder
Table of Contents

Advertisement

6. Electrical Adjustments (Recorder Section)
* Notes:
1, Before the following adjustments
pertorm the input adjustment.
Procedures:
(1)
Connect
an
input connector
to make
the
recorder
section
adjustment
setting.
(Refer
to the Fig.
If-39,)
(2}
Set
the pattern
generator
at white
100%
state.
:
(3)
Adjust the output
level of pattern
generator to 0.49 Vp-p (TP109, R.MAIN
C.B.A.)
* Notes:
2.
REC or EE:
CAMERA MODE
y
PB
=:
~=RECORODER MODE
6-1
SS5V adjustment
R.MAIN C.B.A.
VR603
(SS SV)
5.1 + 0.05 Vv
6-2
Undercut
adjustment
[ Move
rec
[M. £0. [Digital voltmeter, Monitor WV.
'|
[ ADJ.
{GRIP C.B.A, VR2961 (BATT)
TT = 60 + O1H/5.65 +0.1. -0.05 V
Procedures;
(1)
Set a power
sopurce
voltage
at
5.65 V.
(2)
Set the SERVICE Move [S-1] with a
wireless
remote
controller,
(3)
Turn VR until the spec, obtained,
6-3
ATF bias adjustment
Color bar signal
REC PAUSE
Monitor
TV
R.MAIN
C.B.A.
VR401
ATF = 80 + 03H
(ATF)
Proceudres:
(1)
Short-circuit
TP402
(16K)
and TP403
(47K)
of SS C,B.A.
by using
a capacitor.
(Use a capacitor approx. 10,:F/10 V.)
(2)
Set the SERVICE MODE [S-i] with a wire-
less remote
controller.
(3)
To set the REC PAUSE MODE,
change the
RECORDER mode to the CAMERA mode.
(4)
Turn VR until the spec. obtained.
6-4
Switching point adjustment
Monoscope
master
(DY9-1062-000)
PB
Oscilloscope
TP/TRIG.}R.MAIN
C.B.A,
CN110-13PIN
(HSW),
R.MAIN C.B.A,
VR602_
(PG)
SPEC.
7
1H
Equivalent
pulse
3H
V Syne
7H
Head switching
pulse
Fig, 11-62
6-5
AVSV adjustment
[M. €Q. |Oigital voltmeter
TP/TRIG. |R.MAIN C.B.A. -TP102 (AVSV)
| ADJ. _|R.MAIN C.B.A. VRIOI (AV5V)
[seco [5.12 0.05v
CS
6-6 VIDEO LEVEL adjustment
——]
20 mV/10 Us
Fig. I1-63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Canovision8 e50fD15-3230D15-3270

Table of Contents