Technical Specifications; Technical Specifications Nx-8; Technical Specifications Nx-108, Nx-116, Nx-124 - GE NetworX NX-8-EUR Installation Manual

Table of Contents

Advertisement

Technical specifications NX-8

Operating power
- Nominal
- Minimum/maximum
Current consumption
Battery
Maximum recharge time
Auxiliary Power
- Minimal
- Nominal/Maximum
- Maximum ripple
Operating temperature
Loop resistance
- Standard loop
- 2-wire fire loop
Built-in siren driver
Loop response
Dimensions (PCB board only)
Weight (PCB board only)
Classifications
Applied standards
EMC
Environmental
Control and Indicating equipment

Technical specifications NX-108, NX-116, NX-124

Operating power
- Nominal
- Minimum/maximum
Operating temperature
Dimensions
Current consumption
- Minimum (quiescent, no lighting)
- Nominal (quiescent, lighting ON)
Current consumption in alarm
- 1 zone in alarm, sounder/lighting ON
- Maximum (all LED's ON, sounder ON)
Weight
NX-8-EUR Installation manual
T
ECHNICAL SPECIFICATIONS
Page 105
16.5 Vac, 50/60Hz, 35VA
14.05 Vac - 18.15 Vac
Min 100 mA, Max 105 mA
max. 12V/18 Ah
use rechargeable lead-acid battery only
72 hours
EN50131-6 Grade 2 Type A
10.50 Vdc/1.5 A
13.85 Vdc/1.7 A
5%
0 - 50° C
300 Ohms maximum
30 Ohms maximum
112 dB, 2 tones (steady or yelp)
selectable: 50 ms or 500 ms
280 x 90 mm
285 g
Security Grade 2
Environmental Class 2
EN50130-4
EN50130-5
CLC/TS 50131-3
12 Vdc
9 Vdc - 14 Vdc
0 - 50° C
163 x 102 x 26 mm
NX-108
10 mA
29 mA
42 mA
90 mA
228 g
NX-116
NX-124
10 mA
10 mA
29 mA
29 mA
42 mA
42 mA
110 mA
130 mA
230 g
232 g
02/07/06