NECA 365-407-301
4. 06
Automatic
switching takes place when any of the following conditions
oceur:
•
Online
MUX
unit counter failure
•
Online 6M OPT INF unit output signal loss
•
Online transmit monitoring failure detected by the CTRL unit (XMT online
monitoring)
•
Online
DMUX
unit counter failure
e
Online
D~JX
unit frame synchronization loss
•
Online 6M OPT INF unit input signal loss
•
Online receive monitoring failure detected by the CTRL unit (RCV online
monitoring)
•
High speed receive bit-by-bit error detection
•
Low speed output signal loss
•
Low speed channel output failure resulting in
1. 544 Mb
Is
data loss or
incorrect stuffing
C.
DSl Level Remote Loopback
4.07
When loopback circuitry between local and remote equipment is required for
installation testing, etc, remote loopback at DSl (1.544 Mb/s) level is
provided by operation of the
MUX
unit
RLB
switch for appropriate channel. Refer
to Figure 3-7.
4.08
This remote loopback can be performed only when MUX unit ON LINE LED is
lit and is available for both optical and DS2 signals at high speed
(6.312M/s) side.
Page 22