Wiegand Reader Wiring

The RJ45 READER terminals can fully support an 8-wire cable (18-24 AWG). Pref-
erably use the standard FTP cable with RJ45 plug 8-wire CAT6E/7 (recommended)
8-conductor cable.
When using thicker cables (AWG18 - AWG20), an RJ45 -8 screw convertor (P/N:
MPA2RJ) is required to connect the reader to the panel.
For reader cable lengths and power requirements, please look in chapter xxxx.
Figure 3-16 The wire connections are listed below vs the orientation of the RJ45
connector.
Table 3-5 e wire connections are listed below vs the orientation of the RJ45 connector.
52
Reader wire
RJ45 PIN
Colour*
01
White
02
Green
03
Red
04
Black
05
Purple
06
Yellow
07
Orange
Blue
08
Pink
Wiegand
Description
D1
D1 data signal from reader
D0
D0 data signal from reader
Reader power 12VDC from panel OR higher voltage from
12V
external power source**
GND
Reader power 0V / GND
TMP
Tamper from reader
BUZ
Buzzer control from panel
GRN LED
Green LED control from panel
Hold
Hold wire (NOT NEEDED, but can be connected)
Arm
Future use