INSTALLATION INSTRUCTIONS
Electrical connection (non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
44 WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
1
Turn off power supply to outlet.
2
Remove the screw securing the terminal biock
access cover on the back of the dryer.
3
Install a UL-approved strain relief according to the
power cord/strain relief manufacturer's instructions
in the power cord entry hole below the access
panel. At this time, the strain relief should be
loosely in place.
4
Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 10-30 type SRDT, through the
strain relief.
5
Attach the power cord neutral (center wire)
conductor to the SILVER colored center terminal on
the terminal block. Tighten the screw securely.
6
Attach the remaining two power cord outer
conductors to the outer, BRASS colored terminals on
the terminal block. Tighten both screws securely.
44 WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor at
connections.
7
Follow manufacturer's guidelines for firmly securing
the strain relief and power cord.
8
Reinstall the terminal block cover.
=a' IMPORTANT:
If moving dryer from a 4-wire system and installing it
in a 3-wire system, move the internal ground from the
center terminal back to the GREEN screw next to the
terminal block.
30 AMP
NEMA 10-30
Neutral
(center wire)
Neutral
terminal
DO NOT remove
internal ground in a
3-wire system!