INSTALLATION
MANUAL
Flare nut must use a torque wrench without fail. Tighten with the specifi ed tightening
torque. If the fl are nut is tightened too much, after a long period of time, the fl are
nut breaks, Gas leakage, stagnation, touching fi re, rarely cause ignition.
Sharp bending of the pipe use the polyethylene rod, bend not crushed the pipe. Gas
Home
leakage from the crushed part, stagnation, touching fi re, rarely cause ignition.
Please request your sales agent or qualifi ed technician to install your unit. Water
leakage, short circuit or fi re may occur if you do the installation work yourself.
MultiPro
Please observe the instructions stated in the installation manual during the process
of installation. Improper installation may cause water leakage, electric shock and fi re.
A brazed, welded, or mechanical connection shall be made before opening the
valves to permit refrigerant to fl ow between the refrigerating system parts. A vacuum
SPLIT UNIT AIR CONDITIONER
valve shall be provided to evacuate the interconnecting pipe and/or any uncharged
refrigerating system part.
OUTDOOR UNIT
Mechanical connectors used indoors shall comply with ISO 14903. When mechanical
RAM-G36N2HAE
connectors are reused indoors, sealing parts shall be renewed. When fl ared joints
RAM-G43N2HAE
are reused indoors, the fl are part shall be re-fabricated.
Refrigerant tubing shall be protected or enclosed to avoid damage.
Make sure that the units are mounted at locations which are able to provide full
EN INSTRUCTION MANUAL
support to the weight of the units. If not, the units may collapse and impose danger.
Observe the rules and regulations of the electrical installation and the methods
described in the installation manual when dealing with the electrical work. Use power
FOR SERVICE
cables approved by the authorities of your country.
PERSONNEL ONLY
Be sure to use the specifi ed wire for connecting the indoor and outdoor units. Please
ensure that the connections are tight after the conductors of the wire are inserted
into the terminals. Improper insertion and loose contact may cause over-heating and
fi re.
Please use the specifi ed components for installation work. Otherwise, the units may
collapse or water leakage, electric shock and fi re may occur.
Carefully read through the procedures of
proper installation before starting installation
Be sure to use the specifi ed piping set for R32. Otherwise, this may result in broken
work.
copper pipes or faults.
The sales agent should inform customers
When installing or removing an air conditioner, only specifi ed refrigerant (R32) shall be
regarding the correct operation of installation.
allowed, do not allow air or moisture to remain in the refrigeration cycle. Otherwise,
pressure in the refrigeration cycle may become abnormally high so that a rupture
may be caused.
Tools Needed For Installation Work
(
mark is tool exclusive use for R32)
Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas
+ – Screwdriver
Measuring Tape
comes into contact with fi re, a poisonous gas may occur. Be aware that refrigerants
Knife
Saw
Pipe Cutter
may not contain an odour.
Hexagonal Wrench Key (
4mm)
After completion of installation work, check to make sure that there is no refrigeration
Power Drill (ø 65mm ~ ø 80mm)
gas leakage. If the refrigerant gas leaks into the room, coming into contact with fi re
Vacuum Pump
Pliers or Wrench
in the fan-driven heater, space heater, etc., a poisonous gas may occur.
Torque Wrench
Vacuum Pump Adaptor
Unauthorized modifi cations to the air conditioner may be dangerous. If a breakdown
Flare Tool
Gas Leakage Detector
occurs please call a qualifi ed air conditioner technician or electrician. Improper repairs
Manifold Valve
Charge Hose
may result in water leakage, electric shock and fi re, etc.
Reamer
File
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
!
WARNING ........ Incorrect methods of installation may cause death or serious injury.
!
CAUTION ......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the unit as described in the user's guide.
< IA2315: A >
CAUTION
!
A circuit breaker or fuse must be installed. Without a circuit breaker or fuse the danger of electric shock exists.
The external switch shall be incorporated to completely disconnect from power supply. It should disconnect all
poles, and a contact separation of at least 3mm must be present.
Do not install the unit near a location where there is fl ammable gas. The outdoor unit may catch
fi re if fl ammable gas leaks around it.
Do not install the indoor unit in a machine shop or kitchen where vapor from oil or its mist fl ows to the indoor
unit. The oil will deposit on the heat exchanger, thereby reducing the indoor unit performance and may deform
and in the worst case, break the plastic parts of the indoor unit.
Please ensure smooth fl ow of water when installing the drain hose.
Piping shall be suitable supported with a maximum spacing of 1m between the supports.
!
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer. Any unfi t method or using incompatible material may cause product damage, burst and serious
injury.
The appliance/pipe-work shall be stored in a well ventilated room with indoor fl oor area larger than A
to Table 1] and without any continuously operating ignition source. Keep away from open fl ames, any operating
gas appliances or any operating electric heater. Else, it may explode and cause injury or death.
The appliance/pipe-work shall be installed, and/or operated in a room with fl oor area larger than A
Table 1] and keep away from ignition sources, such as heat/spark/open fl ame or hazardous areas such as gas
appliances, gas cooking, reticulated gas supply systems or electric cooking appliances, etc.
Do not pierce or burn as the appliance/pipe-work is pressurized. Do not expose the appliance/pipe-work to heat,
fl ame, sparks, or other sources of ignition. Else, it may explode and cause injury or death.
1. Proper place for installation
1.1 Outdoor unit
(1) Keep the space around the unit for maintenance and avoiding the effects of hindrance for normal ventilation of the
unit.
(2) The northern or eastern side of the building is better to install. At the installation on the southern or western side
unavoidably, some blind should be set up for the unit. (In this case, the blind must not obstruct the ventilation of
the unit.)
(3) You'd better not put the unit at a place where is full of dirt and at a place where is wet in the rain.
(4) Place as near as possible to the indoor unit.
(5) Install the unit in a stable place to minimize vibration or noise.
(6) After arranging the cords and pipes, secure them in place.
This appliance must be earthed.
!
WARNING
Power is supplied through outdoor unit, do not connect power source to indoor unit.
2. In the electrical installation a separator with a contact gap of more than 3mm has to be installed. During cleaning or
service the set has to be switched off with this separator.
<
>
IA2315: A
WARNING
!
WARNING
min
The Choice of Mounting Site
WARNING
!
The Outdoor unit must be mounted at a location which can support
heavy weight. Otherwise, noise and vibration will increase.
CAUTION
!
Do not expose the unit under direct sunshine or rain. Besides,
ventilation must be good and clear of obstruction.
The air blown out of the unit should not point directly to animals
or plants.
The clearances of the unit from top, left, right and front are
specifi ed in fi gure below. At least 3 of the above sides must be
open air.
Be sure that the hot air blown out of the unit and noise do not
disturb the neighbourhood.
Do not install at a location where there is fl ammable gas, steam,
oil and smoke.
The location must be convenient for water drainage.
Place the Outdoor unit and its connecting cord at least 1m away
from the antenna or signal line of television, radio or telephone.
This is to avoid noise interference.
Do not install outdoor unit facing strong wind direction. It may
damage the fan motor.
Do not install the outdoor unit in a place where small animals
may build their nests. If small animal goes inside the unit and
touches the electrical parts, failure of the unit, smoke or fi re may
be caused. Request your customer to keep the surrounding of
the unit is clean.
WARNING
This symbol shows that this
equipment uses a fl ammable
refrigerant.
If the refrigerant is leaked,
together with an external
ignition source, there is a
possibility of ignition.
CAUTION
This symbol shows that the
Operation Instructions should
be read carefully.
CAUTION
This symbol shows that a
service personnel should be
handling this equipment with
reference to the Installation
Manual.
CAUTION
This symbol shows that there
is information included in
the Operation Manual and/or
Installation Manual
above 100mm
above 700mm
Height difference
Height difference between indoor units should not be
more than 5m.
[refer
min
[refer to
CAUTION
!
Make sure to connect to two indoor units.
To the outdoor unit, up to two indoor units can be connected until the total nominal cooling capacity not more than
5.0 kW (RAM-G36N2HAE), 6.0 kW (RAM-G43N2HAE).
The pipe connection ports of the outdoor unit and connectable indoor units are shown above.
(Please note the following matters and obtain permission from customer before installation).
Names of Outdoor Components
No.
Item
Qty
Bush
1
Drain Pipe
2
Bush
3
Figure showing the Installation of Outdoor Unit.
CAUTION
!
This unit is chargeless up 35m pipe length.
Installation of pipe length less than minimum pipe length
requirement (3 meters) may generate an abnormal sound.
!
WARNING
BURST HAZARD
Do not allow air, etc. to get into refrigerant cycle (piping)
RISK OF EXPLOSION
Compressor must be stopped before removing refrigerant pipes.
All service valve must be fully closed after pumping down operation.
Be sure to
completely
seal any gap
above 100mm
with putty.
Refrigerant piping
must be protected
from physical
damage. Install a
plastic cover or
equivalent.
above 200mm
above 100mm
give
clearance
as wide as
possible
above 200mm
Piping length
(L1 + L2) = Maximum 35m
Minimum piping length for each indoor unit is 3m.
Maximum piping length for one indoor unit is 25m.
Additional charge of refrigerant is not required.
Flare adaptor for piping
The fl are adaptor for piping is required depending on
combination of indoor units.
ø9.52(3/8") ➝ ø 12.7 (1/2")
Parts number TA261D-4 001
One unit of 1.5kW, 1.8kW, 2.5kW, 3.5kW
*
One unit of 1.5kW, 1.8kW, 2.5kW, 3.5kW,
4.2kW
(4.2kW unit: Optional fl are adaptor for piping is necessary.)
*
RAM-G43N2HAE
Dimension of Mounting Stand
of the Outdoor unit
2
(unit : mm)
mounting stand
1
1
WARNING
!
Flare connection only at outside
of building
The indoor piping should
be insulated with the
enclosed insulation
pipe. (If the insulator is
insuffi cient, please use
commercial products).
The difference in height
between the indoor and
outdoor unit should be
kept max 10m.
The connecting pipe,
no matter big or small,
should all be insulated
with insulation pipe and
then wrapped with vinyl
tape. (The insulator will
deteriorate if it is not
wrapped with tape).
The connection of insulated
drain hose.
inner diameter ø 16mm
Please use insulated drain
hose for the indoor piping
(commercial product).

Advertisement

loading

Summary of Contents for Hitachi airHome MultiPro RAM-G36N2HAE

  • Page 1 The Choice of Mounting Site (Please note the following matters and obtain permission from customer before installation). Names of Outdoor Components WARNING INSTALLATION WARNING The Outdoor unit must be mounted at a location which can support ● Item Dimension of Mounting Stand heavy weight.
  • Page 2 Please mount the Outdoor unit on stable ground to prevent vibration ● Preparation of Pipe Removal Of Air From The Pipe And Gas Leakage Inspection and increase of noise level. Decide the location for piping after sorting out the different types of ●...

This manual is also suitable for:

Airhome multipro ram-g43n2hae