Page 1
Models Monozone/Multizone (NH5/NH6/NH7/QH5) Summit (YH5/FH5/YH6) Monoduct (DH7) Bigflow (GH4/G4) Air Exchanger (JX5) ROOM AIR CONDITIONERS room conditioners...
Page 3
Contents Company profile Standards and quality certificates Product range overview General features and benefits Monozone/Multizone range Summit range Monoduct range Bigflow range Air Exchanger range...
Page 4
As one of the largest after sales service. companies in the world, Hitachi is well positioned to undertake this commitment with confidence that Hitachi Authorised Distributors are comes from successfully...
Page 5
International Standard Quality Management System ISO9001 and ISO14001 authorisation. The Tochigi Works performs thorough product quality control using various environmental tests. Hitachi Room Air Conditioning Indoor and Outdoor units are manufactured according to this ISO certification system. Hitachi products all carry the necessary ‘CE’...
Page 6
The Hitachi range of Room Air development and testing facilities Conditioners feature a vast array • Zone by zone heating or cooling at various Hitachi factories and...
100% power factor to enhance inverter PAM technology helps us power efficiency. This cutting edge to achieve the ‘A’ class, the highest device is employed in all Hitachi level of energy efficiency which is Mono/Multizone products for your clearly indicated on the standard comfort and energy saving for our labelling system.
Digital DC Scroll DC Twin Rotary Compressor Compressor Today all Monozone and two Multizone room air conditioning units have Hitachi’s The motor uses digital control to new twin rotary compressor which has even maximise PAM control performance. less vibration and even higher performance •...
Page 10
Air Quality Either the SPX-CFH5 or SPX-CFH11, washable carbon and anti-bacteria air purifying filters are included in all of Hitachi’s room air conditioning products. This ensures that the micro dust, pollen particles and odours that can collect on filters can be easily removed. The filters can be washed and reused up to 20 times.
Page 11
Hitachi have now enhanced it by reducing its size to a nanometer The Nano-Titanium does not – over 1000 times smaller than deteriorate or run out as particles ordinary bacteria agent.
Page 13
The Hitachi Multizone range was the worlds first all DC Inverter Multisplit You can choose and connect freely from different types of indoor and outdoor system with zone by zone cooling or heating for up to four rooms.
Page 14
RAK Technical Description Hitachi’s R410A All DC Inverter Ranges elevate air conditioning to a new level, incorporating significant advances in electronics technology. With cooling and heating capacities from 2.0kW to 5.0kW, the all DC Inverter PAM driven mono split Monozone/Multizone Framed Flat...
Page 16
RAK Technical Description Powerful A bigger, compact flap delivers air quickly to every corner of the room and • Powerful the powerful, sweeping air flow eliminates dead zones and improves the • Silent cooling and heating effect. • Efficient • Clean Wide and Big Air Flap Silent The trapezoidal blades cut the air diagonally to minimise air resistance and...
Page 17
General Data Model RAK-18NH5 RAK-25NH5 RAK-35NH5 RAK-50NH5 RAK-65NH5 Power Supply DC 35V DC 35V DC 35V DC 35V DC 35V Sound Pressure Level (Overall Scale) 35/30/26/20 38/32/26/20 41/35/29/25 47/39/31/27 47/42/33/28 Cooling 36/33/27/23 39/33/27/23 41/35/30/26 47/39/31/27 47/42/34/33 Heating Outer Dimensions (Net/(Carton) 280(254) 280(254) 280(254)
Page 18
RAF Technical Description Comfortable heating The air flow from the upper and lower outlets enables the whole room to be heated evenly, from the floor to the ceiling. Large and gentle air flow is generated by the larger upper blades, achieving efficient air conditioning.
Page 19
General Data Model RAF-25NH5 RAF-35NH5 RAF-50NH5 Power Supply DC 35V DC 35V DC 35V Sound Pressure Level (Overall Scale) 35/31/26/23 40/35/28/24 44/37/28/24 Cooling 35/31/26/25 41/35/31/26 44/39/34/31 Heating Outer Dimensions (Net/(Carton) 600(656) 600(656) 600(656) Height 750(797) 750(797) 750(797) Width 215(278) 215(278) 215(278) Depth 15(17)
Page 20
RAI Technical Description Fits into 60cm x 60cm ceiling module With it’s the compact design the 60cm x 60cm ceiling unit neatly fits inside a standard ceiling module which minimises the installation work. Silent The noise level is just 25dB (sleep mode) thanks to the 3D – twisted wing design of the compact turbo-fan.
Page 21
General Data Model RAI-25NH5 RAI-35NH5 RAI-50NH5 RAI-ECPM Power Supply DC 35V DC 35V DC 35V DC 35V Sound Pressure Level (Overall Scale) 35/32/29/25 39/34/29/26 43/35/32/29 – Cooling 36/33/30/27 40/36/32/29 43/36/32/30 – Heating Outer Dimensions (Net/(Carton) 285(395) 285(395) 285(395) 650(710) Height 580(760) 580(760) 580(760)
Page 22
RAD Technical Description • Compact design – 750 mm wide and 235 mm high • Newly developed wired remote controller with built in 12 hour timer • Optional remote controller also available using SPX-RCK1 remote control kit •Air in-take pre filter as standard •...
Page 23
General Data Model RAD-18NH7 RAD-25NH7 RAD-35NH7 RAD-50NH7 Power Supply DC 35V DC 35V DC 35V DC 35V Sound Pressure Level (Overall Scale) 36/34/31/29 36/34/31/29 36/34/31/29 38/35/32/29 Cooling 37/33/30/27 37/33/30/27 37/33/30/27 38/35/32/29 Heating Outer Dimensions (Net/(Carton) 235(306) 235(306) 235(306) 235(306) Height 750(806) 750(806) 750(806)
Outdoor units The table below shows the units available in all kW capacities and the usual application. Monozone 1* Multizone 2** Multizone 3** Multizone 4** Multizone 5** Multizone 6** (1 Room) (2 Rooms) (3 Rooms) (4 Rooms) (5 Rooms) (6 Rooms) Model 25NH5 35NH5...
Page 26
Monozone/Multizone Combinations continued Monozone 1* Multizone 2** Multizone 3** Multizone 4** Multizone 5** Multizone 6** (1 Room) (2 Rooms) (3 Rooms) (4 Rooms) (5 Rooms) (6 Rooms) RAC-25NH5 RAC-35NH5 RAC-50NH5 RAC-65NH5 RAM-40QH5 RAM-55QH5 RAM-65QH5 RAM-72QH5 RAM-80QH5 RAM-90QH5 RAM-130QH5 Model Combination of Indoor Unit Combination Total 1.8 1.8...
Page 27
Monozone/Multizone Combinations continued Monozone 1* Multizone 2** Multizone 3** Multizone 4** Multizone 5** Multizone 6** (1 Room) (2 Rooms) (3 Rooms) (4 Rooms) (5 Rooms) (6 Rooms) RAC-25NH5 RAC-35NH5 RAC-50NH5 RAC-65NH5 RAM-40QH5 RAM-55QH5 RAM-65QH5 RAM-72QH5 RAM-80QH5 RAM-90QH5 RAM-130QH5 Model Combination of Indoor Unit Combination Total 1.8 1.8...
Page 28
Monozone – Technical Description General Data Indoor RAK-25NH6 RAK-35NH6 RAK-50NH6 Model Outdoor RAC-25NH5 RAC-35NH5 RAC-50NH5 Power Supply AC 1Ph 220-230V 50Hz Nom. Cooling Capacity 2.5(1.0-3.1) 3.5(1.0-4.0) 5.0(0.9-5.2) (min-max) Nom. Heating Capacity 3.5(0.9-5.0) 4.8(0.9-6.6) 6.5(0.9-8.1) (min- max) Total Input 695(155-1050) 1080(155-1280)
Page 29
Monozone – Technical Description General Data Indoor RAK-25NH5 RAK-35NH5 RAK-50NH5 RAK-65NH5 Model Outdoor RAC-25NH5 RAC-35NH5 RAC-50NH5 RAC-65NH5 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 2.5(0.9-3.0) 3.5(0.9-4.0) 5.0(0.9-5.2) 6.05(0.9-6.5) Nominal (min- max) Heating Capacity 3.5(0.9-5.0) 4.8(0.9-6.6) 6.5(0.9-8.1) 7.05(0.9-9.0) Total Input 695(155-1050) 1080(155-1280)
Page 30
Monozone – Technical Description General Data Indoor RAF-25NH5 RAF-35NH5 RAF-50NH5 RAI-25NH5 RAI-35NH5 RAI-50NH5 Model Outdoor RAC-25NH5 RAC-35NH5 RAC-50NH5 RAC-25NH5 RAC-35NH5 RAC-50NH5 Power Supply AC 1Ph 220-230V 50Hz Nom. (min-max) Cooling Capacity 2.5(0.9-3.0) 3.5(0.9-4.0) 5.0(0.9-5.2) 2.5(0.9-3.0) 3.5(0.9-4.0) 5.0(0.9-5.2) Nom. (min- max) Heating Capacity 3.5(0.9-5.0) 4.8(0.9-6.6) 6.7(0.9-8.1)
Page 31
Monozone – Technical Description General Data Indoor RAD-25NH7 RAD-35NH7 RAD-50NH7 Model Outdoor RAC-25NH5 RAC-35NH5 RAC-50NH5 Power Supply AC 1Ph 220-230V 50Hz Nom. Cooling Capacity 2.5(0.9-3.0) 3.5(0.9-4.0) 5.0(0.9-5.6) (min-max) Nom. Heating Capacity 3.5(0.9-5.0) 4.8(0.9-6.6) 6.0(0.9-7.5) (min- max) Total Input 695(155-1050) 1240(155-1280) 2000(155-2060) Cooling 970(155-1400)
Page 32
Multizone – Technical Description General Data Model RAM-40QH5 RAM-55QH5 RAM-65QH5 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 4.0 (1.0-4.5) 5.4 (1.5-5.9) 6.3 (1.5-6.6) Nominal (min- max) Heating Capacity 5.0 (1.1-5.6) 7.2 (1.5-7.2) 7.2 (1.5-7.2) Sound Pressure Level (Overall Scale) 49(43) 52(45) 52(45)
Page 33
Multizone – Technical Description General Data Model RAM-72QH5 RAM-80QH5 RAM-90QH5 RAM-130QH5 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 7.1(2.4-8.8) 8.0(3.0-9.2) 9.0(3.2-9.9) 12.6(1.50-13.20) Nominal (min- max) Heating Capacity 8.6(2.6-9.5) 11.0(3.0-12.4) 11.0(3.4-12.1) 14.4(1.50-14.40) Sound Pressure Level (Overall Scale) 53(46) 49(43) 55(46) 55(48)
Page 34
Monozone/Multizone Combinations RAC-25/35/50/65NH5 Cooling Mode Heating Mode Combination of Total Total Total Total Total Total Indoor Units Capacity (kW) Input (W) Current (A) Capacity (kW) Input (W) Current (A) RAK-25NH5/NH6 3.20 3.60 4.15 3.89 (0.9-3.0) (155-1050) (0.9-5.0) (115-1400) RAF-25NH5 3.20 3.60 4.15 3.89...
Page 35
Multizone Combinations RAM-55QH5 Cooling Mode Heating Mode Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Total Total Capacity Total Total (kW) Total Total (kW) (kW) Input (W) Current (A) (kW) Input (W) Current(A) 1.80 2.50 1.80 3.21 2.50 3.33 (1.00-2.50) (200-750)
Page 36
Multizone Combinations RAM-72QH5 Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Total Total Capacity Total Total (kW) Total Total (kW) (kW) Input (W) Current (A) (kW) Input (W) Current (A) 1.80 2.50 4.00 2.94 (1.50-2.00) (280-500) (1.80-3.50) (320-1130) 2.50...
Page 37
Multizone Combinations RAM-72QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Total Total Capacity Total Total (kW) Total Total (kW) (kW) Input (W) Current (A) (kW) Input (W) Current (A) 1.8+2.5+2.5 2040 2.3+3.15+3.15 2290 1.8+2.5+2.5 3.33 10.1 3.76...
Page 38
Multizone Combinations RAM-80QH5 Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Total Total Capacity Total Total (kW) Total Total (kW) (kW) Input (W) Current (A) (kW) Input (W) Current (A) 1.80 2.50 3.21 3.62 (1.00-2.50) (360-750) (1.10-3.20) (320-970) 2.50...
Page 39
Multizone Combinations RAM-80QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Total Total Capacity Total Total (kW) Total Total (kW) (kW) Input (W) Current (A) (kW) Input (W) Current (A) 1.8+2.5+5.0 1.50+2.00+4.50 2580 2.00+3.00+5.20 2530 11.3 3.10 10.2...
Page 40
Multizone Combinations RAM-90QH5 Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V 1.80 2.50 1.80 3.60...
Page 41
Multizone Combinations RAM-90QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V 1.8+2.5+3.5 2190 2.3+3.13+3.97...
Page 42
Multizone Combinations RAM-90QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V 1.80+1.80+1.80+1.80 1800 2.4+2.4+2.4+2.4...
Page 43
Multizone Combinations RAM-90QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V 1.05+2.05+2.95+2.95 2510 1.39+2.39+3.61+3.61...
Page 44
Multizone Combinations RAM-90QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V 1.06+1.06+1.06+2.91+2.91 2360 1.34+1.34+1.34+3.49+3.49...
Page 45
Multizone Combinations RAM-130QH5 Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V 1.80 2.50 1.80 3.21...
Page 46
Multizone Combinations RAM-130QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V (1.80+2.40)+(1.70+3.30) 2960 (2.40+3.80)+(2.30+4.50)
Page 47
Multizone Combinations RAM-130QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V (1.8+1.8)+ (1.80+1.80)+ 2970...
Page 48
Multizone Combinations RAM-130QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V (3.5+3.5)+ (2.70+2.70)+ 3890...
Page 49
Multizone Combinations RAM-130QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) Total (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V (1.8+1.8+3.5)+ (1.60+1.60+3.10)+ 4190 (1.85+1.85+3.50)+ 3800 (1.8+1.8+5.0) 15.7...
Page 50
Multizone Combinations RAM-130QH5 continued Cooling Heating Combination Outdoor Unit Outdoor Unit of Indoor Unit Total Capacity Rating Total Power Ampere(A) Capacity Rating Power Ampere(A) (kW) – – Total (kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V (1.8+3.5+3.5)+ (1.30+2.50+2.50)+ 4190...
Page 51
PM RAS-51 CHA1 SPX-RCK1 Wireless Remote Control Wireless Remote Control Kit Standard wireless remote control Wireless remote control which can compatible with most of the be used in place of the standard Mono/Multizone, Summit and wired remote control used for Bigflow range.
Page 52
RAS/RAC Technical Description Hitachi’s R410A All DC Inverter Ranges elevate air conditioning to a new level, incorporating significant advances in electronics technology. With cooling and heating capacities from 2.5kW to 5.0kW, the all DC Inverter PAM driven mono split SUMMIT Framed Flat range incorporates the R410A refrigerant, Hitachi DC Scroll, or DC Twin Rotary compressor all working together for high performance and ultimate efficiency.
Page 53
General Data Indoor RAS-25FH5 RAS-35FH5 RAS-50FH5 Model Outdoor RAC-25YH5 RAC-35YH5 RAC-50YH5 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 2.5(0.9-3.1) 3.5(0.9-4.0) 5.0(0.9-5.2) Nominal (min- max) Heating Capacity 3.4(0.9-4.4) 4.2(0.9-5.0) 6.5(0.9-8.1) Total Input 580(155-1080) 980(155-1300) 1780(155-2200) Cooling 790(115-1120) 1010(115-1300) 1970(155-2100) Heating Total Current 3.11-2.97...
Page 54
RAS/RAC Technical Description Hitachi’s R410A All DC Inverter Ranges elevate air conditioning to a new level, incorporating significant advances in electronics technology. With cooling and heating capacities from 2.0Kw to 8.0Kw, the all DC Inverter PAM driven mono split SUMMIT range incorporates the R410a refrigerant, Hitachi DC Scroll, or DC Twin Rotary compressor all working together for high performance and ultimate efficiency.
Page 55
General Data Indoor RAS-18YH5 RAS-25YH5 RAS-35YH5 RAS-50YH5 RAS-60YH5 RAS-70YH5 RAS-80YH5 Model Outdoor RAC-18YH5 RAC-25YH5 RAC-35YH5 RAC-50YH5 RAC-60YH5 RAC-70YH5 RAC-80YH5 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 2.0(0.9-2.5) 2.5(0.9-3.1) 3.5(0.9-4.0) 5.0(0.9-5.2) 6.05(0.9-6.5) 7.0(0.9-8.0) 8.0(1.5-8.5) Nominal (min- max) Heating Capacity 2.5(0.9-3.2) 3.4(0.9-4.4) 4.2(0.9-5.0)
Page 56
RAS/RAC Technical Description Hitachi’s R410A All DC Inverter Ranges elevate air conditioning to a new level, incorporating significant advances in electronics technology. With cooling and heating capacities from 2.0kW to 3.5kW, the all DC Inverter PAM driven mono split SUMMIT range incorporates R410A refrigerant and the Hitachi DC Rotary compressor all working together for high performance and ultimate efficiency.
Page 57
General Data Indoor RAS-18YH6 RAS-25YH6 RAS-35YH6 Model Outdoor RAC-18YH6 RAC-25YH6 RAC-35YH6 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 2.0(0.9-2.5) 2.5(0.9-3.1) 3.5(0.9-4.0) Nominal (min- max) Heating Capacity 2.5(0.9-3.2) 3.4(0.9-4.4) 4.2(0.9-5.0) Total Input 550(155-1010) 700(155-1290) 1090(155-1460) Cooling 580(115-970) 880(115-1250) 1110(115-1440) Heating Total Current 2.95-2.81...
Page 58
RAS/RAC Technical Description Hitachi has extended its room air conditioning offering to include the new Monoduct range. The R410A, all DC Inverter range of ‘In-the-ceiling’ units are ideal for light commercial and residential use. • DC Inverter PAM Control • Low noise down to 28dBA on sleep mode •...
Page 59
General Data Indoor RAD-50DH7 RAD-60DH7 RAD-70DH7 Model Outdoor RAC-50DH7 RAC-60DH7 RAC-70DH7 Power Supply AC 1Ph 230V 50Hz Nominal (min-max) Cooling Capacity 5.0(0.9-6.0) 6.0(0.9-7.0) 7.1(0.9-8.0) Nominal (min-max) Heating Capacity 6.0(0.9-7.0) 7.3(0.9-8.0) 8.0(0.9-9.0) Total Input 1400(200-2100) 1870(200-2500) 2530(200-2920) Cooling 1590(200-2200) 2130(200-2600) 2340(200-3100) Heating Total Current 6.15...
Page 60
RAS/RAC Technical Description The Hitachi R410A mono split system offers a cost effective and efficient solution to climate control in one zone. With cooling only and heat pump models available and with their compact design, reliability and high efficiency, this range is suited to a wide variation of applications.
Page 61
General Data Indoor RAS-07GH4 RAS-09GH4 RAS-14GH4 RAS-18GH4 RAS-24GH4 Model Outdoor RAC-07GH4 RAC-09GH4 RAC-14GH4 RAC-18GH4 RAC-24GH4 Power Supply AC 1Ph 220-240V 50Hz Nominal (min-max) Cooling Capacity Nominal (min-max) Heating Capacity 3.85 5.75 Total Input 1090 1580 2490 Cooling 1000 1680 2660 Heating Total Current 7.23...
The Air Exchanger range of Hitachi’s room air conditioning products work as the name suggests by exchanging room air with fresh air by a unique two-way Air Exchange System. It also includes the all DC Inverter PAM control which significantly improves the system’s performance and efficiency.
Page 63
The key features are: Two-way Air Exchange The new air exchanger includes a specially designed rotary damper and air pipe which ensures the effective refresh of the room environment. This unique function enables the CO , and other pollutants that would not be caught by the normal air purifying function to be exhausted outside of the room and fresh air is then let into the room.
Page 64
Installation Again as with most Hitachi room air conditioning units, installation is simple. The Air Exchanger has an air pipe that is open outside of the wall with the refrigerant pipes, and no additional. The units all come with a Ventilation Accessory Kit which includes an air pipe which is 2.5m length, insect net...
Page 65
General Data Indoor RAS-25JX5 RAS-35JX5 Model Outdoor RAC-25JX5 RAC-35JX5 Power Supply AC 1Ph 220-230V 50Hz Nominal (min-max) Cooling Capacity 2.5(0.9-3.1) 3.5(0.9-4.0) Nominal (min-max) Heating Capacity 3.4(0.9-4.4) 4.2(0.9-5.0) Total Input 580(155-1160) 990(155-1380) Cooling 795(115-1170) 1040(115-1350) Heating Total Current 3.11-2.97 4.74-4.54 Cooling 4.02-3.85 4.98-4.76 Heating...
Page 68
Specifications in this catalogue are subject to change without notice in order that HITACHI may bring the latest innovations to their customers. Omitting typing errors. Hitachi Europe Ltd Whitebrook Park Lower Cookham Road Maidenhead Berkshire SL6 8YA Distributed by: United Kingdom email: aircon.enquiries@hitachi-eu.com...