3. Maintenance
CAUTION
Use genuine Panasonic replacement parts to keep safe
and long durable operation.
3.1 Daily maintenance
Parts
Contact tip
Nozzle
Wave washer
Liner
Inner tube
3.2 Replacement of Inner tube
Turn Nut cover and remove Connector from Power
cable. Pull Inner tube out of Torch body.
OM0707095JE06
Before operation, turn off all input power for welding power source, robot
controller and all equipment connected.
Check it before daily operation. Replace a large hole tip.
Check it before daily operation. Replace a deformed nozzle.
Replace a flattened wave washer that has lost spring tension.
Clean it every week. Replace a
Clean it with solvent. Replace a tube with deformed entrance.
Maintenance
bent
or deformed liner.
1
2
3
1
2
3
4
5
Maintenance
4
5
Torch body
Connector
Inner tube
Nut cover
Power cable
11