  • Page 4: Safety Instructions

    SAFETY INSTRUCTIONS IMPORTANT TO BE READ AND OBSERVED • Download the complete instruction manual on docs.whirlpool.eu or call the phone number shown on the warranty booklet. • Before using the appliance, read these safety instructions. Keep them nearby for future reference.
  • Page 5: Installation

    SAFETY INSTRUCTIONS INSTALLATION The appliance must be handled and installed by two or more persons - risk of injury. Use protective gloves to unpack and install - risk of cuts. Installation, including electrical connections, and repairs must be carried out by a qualified technician according to national wiring rules.
  • Page 6: Declaration Of Conformity

    This symbol shows that information is available such as the operating manual or installation manual SAFETY INSTRUCTIONS FOR SERVICING APPLIANCE WITH SPESIFIC REFRIGERANT Download the complete manual for detailed installation, servicing, maintenance and repairing methods on docs.whirlpool.eu. - 6 -...
  • Page 7 SAFETY INSTRUCTIONS Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation; without continuously operating ignition sources (such as;...
  • Page 8 SAFETY INSTRUCTIONS 6-5 Presence of fire extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. 6-6 No ignition sources No person carrying out work in relation to a refrigerating system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of...
  • Page 9 SAFETY INSTRUCTIONS 7. Repairs to sealed components During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
  • Page 10 SAFETY INSTRUCTIONS - If a leak is suspected, all naked flames shall be removed/ extinguished. - If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
  • Page 11 SAFETY INSTRUCTIONS b. Isolate system electrically. c. Before attempting the procedure ensure that: - Mechanical handling equipment is available, if required, for handling refrigerant cylinders; - All personal protective equipment is available and being used correctly; - The recovery process is supervised at all times by a competent person; - Recovery equipment and cylinders conform to the appropriate standards.
  • Page 12 SAFETY INSTRUCTIONS Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinstallation of the unit.
  • Page 13 Product Description 1. Control Panel and Digital 2. Handle 3. Air Inlet 4. Air Outlet 5. Water Bucket 6. Water Level Display 7. Castor Wheels 8. Continuous Draining Hose Connection 9. Filter 10. Humidity Indicator Light - 13 -...
  • Page 14 User Interface FAN SPEED CHILD LOCK SLEEP TIMER HUMIDITY DEHUMIDIFY POWER SETTING MOOE 11. POWER BUTTON 20. Full bucket indicator Press to turn on/off the unit 21. Defrost Indicator 12. DEHUMIDIFY MODE BUTTON 22. Sleep Indicator Used to select the operating mode: Normal, Continuous, 6 sense, Laundry program.
  • Page 15: How To Use The Appliance

    HOW TO USE THE APPLIANCE FIRST-TIME USE the bucket is full or not inserted properly, the Water After transporting or handling the appliance, wait one Full indicator (20), full bucket indicator lights up and hour, before connecting it to the power supply, make sure that the appliance rests in the upright position, stops the appliance (read the “Water bucket full function”...
  • Page 16 FUNTION DESCRIPTIONS TIMER FUNCTION CHILD LOCK FUNCTION Press the “TIMER” button (17) to set the Timer Press and hold the “CHILD LOCK”(18) button on/off. The “Hr”(30) indicator in the LED display for 3seconds to lock all controls. The (19) lights up. The timer can be set with 1h (one lights up.
  • Page 17: Water Drainage

    WATER DRAINAGE DRAINING WATER THROUGH THE WATER BUCKET The Water Full indicator(20) lights up when the water bucket is full. The machine stops automatically and the water bucket will have to be emptied. 1. Remove the water bucket Gently pull water bucket out from the back of the dehumidifier.
  • Page 18: Continuous Drainage

    CONTINUOUS DRAINAGE 1. Remove the buck et 2. Connect the drainage hose (diameter 10mm ) to the drain hole and ensure there is no water leaks out. 3. Ensure the horizontal height of drainage hose should not exceed the height of the drainage outlet.
  • Page 19: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING THE DEHUMIDIFIER 1. Switch the unit off and unplug it. 3. Do not use petrol or solvents. 2. Clean the air inlet (3) and outlet (4) using a soft cloth. 4. Clean the surface with a soft damp cloth, using Dust tends to accumulate in these points.
  • Page 20: Safe Operation

    INSTALLATION GUIDE min50cm min20cm from the back min20cm from the front min20cm from Horizontal distance min 50 the left and right cm between the clothes and the air outlet 11. The dehumidifier has rollers to aid its positioning. Do 1. Place the appliance in the upright position on a stable and flat surface to prevent leakages.
  • Page 21: Troubleshooting

    TROUBLE SHOOTING What to do if …. Possible reasons / Solutions Noise suddenly occurs during Noise occurs if the compressor has just activated. operation. • The area to be dehumidified is too large. Your dehumidifier’s capacity may be inadequate. The humidity does not decrease. •...
  • Page 22: After Sales Service

    AFTER-SALES SERVICE Before contacting the Customer Care Centre: If repair work has to be carried out, contact the 1. Try to solve the problem yourself based on the Customer Care Centre (Use of original spare parts and descriptions given in the “ Troubleshooting” . a proper repair is guarenteed).