Download Print this page
Sealey ML18/36.V2 Instructions
Sealey ML18/36.V2 Instructions

Sealey ML18/36.V2 Instructions

Rechargeable emergency lantern

Advertisement

Quick Links

mODEL No:
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREmENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO mAY CAUSE DAmAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1
.
1.
SAFETY
1.1.
ELECTRICAL SAFETY.
WARNING! It is the user's responsibility to read, understand and comply as follows. You must check all electrical
equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation
of appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution
board. We also recommend that an RCD (Residual Current Device) is used with all electrical products. It is
particularly important to use an RCD together with portable products that are plugged into an electrical supply not
protected by an RCCB.
If in doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your
Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1.
The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises,
to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the
appliance, and the safety of the appliance operator. If in doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure the insulation on all cables and the product itself is safe before connecting to the mains power
supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).
1.1.4.
Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply, leads and plugs for wear and damage and inspect connections to ensure that none is
loose.
1.1.6.
Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used, and check
that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse smaller than 13 amps for certain
products, see fuse rating at right.
1.1.7.
DO NOT pull or carry the powered appliance by its power supply lead.
1.1.8.
DO NOT pull power plugs from sockets by the power cable.
1.1.9.
DO NOT use worn or damaged leads, plugs or connections.
Immediately replace or have repaired by a qualified electrician.
A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage,
cut off and fit a new plug according to the following instructions (discard
old plug safely). (UK only - see diagram at right).
Ensure the unit is correctly earthed via a three-pin plug.
a) Connect the green/yellow earth wire to the earth terminal 'E'.
b) Connect the brown live wire to live terminal 'L'.
c) Connect the blue neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have
been correctly connected, that the cable outer insulation extends
beyond the cable restraint and that the restraint is tight.
Double insulated products are fitted with live (BROWN) and
neutral (BLUE) wires only. Double insulated products are always marked
with this symbol
indicated above. DO NOT connect the brown or blue to the earth terminal.
1.1.10. Cable extension reels. When a cable extension reel is used it should be fully
unwound before connection. A cable reel with an RCD fitted is recommended
since any product which is plugged into the cable reel will be protected.
1.2.
GENERAL SAFETY
WARNING! Disconnect lamp from mains power before changing tubes or performing any maintenance.
 Replace or repair damaged parts. Use genuine Sealey parts only. Non-authorised parts may be dangerous and will invalidate
the warranty.
 Maintain the lamp in good condition.
 DO NOT use the lamp if damaged.
 DO NOT use lamp close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning
rags.
 DO NOT fit a fluorescent tube other than the recommended replacement. (SEALEY PART NO. 003-SD1824D)
 When not in use switch off the lamp and remove plug from power supply, unless being used as emergency lighting.
. To re-wire, connect the brown and blue wires as
Original Language Version
INSTRUCTIONS FOR:
RECHARGEABLE
EmERGENCY LANTERN
mL18/36.V2
Blue
Neutral
wire
Yellow & Green
Earth wire
Brown
Live
wire
Cable
restraint
FUSE RATING
THIS PRODUCT mUST
BE
FITTED WITH A
3 AmP FUSE
ML18/36.V2
Issue: 2 - 12/10/09

Advertisement

loading

Summary of Contents for Sealey ML18/36.V2

  • Page 1 No: Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREmENTS, WARNINGS AND CAUTIONS.
  • Page 2 3.3.3 After a full charge the lantern will run for approximately 1hr 45min on two tubes and 3hr 45min on one tube. NOTE! The green LED will light whenever a bulb should be lit. If the tubes DO NOT light and the green LED is lit, suspect a faulty tube. Original Language Version ML18/36.V2 Issue: 2 - 12/10/09...
  • Page 3 4.1.1 Replacement tubes must be the same type 1 BULB FUNCTION and rating as the original tubes supplied. SWITCH Use Sealey replacement tubes (PART NO. 003-SD1824D) 4.1.2 Remove the transparent cover by removing the mAINS two cover screws and lifting away the CONNECTED transparent cover.