Download Print this page
Philips HD7810/31/E Service Manual

Philips HD7810/31/E Service Manual

Advertisement

Quick Links

Philips Consumer Lifestyle
Service Manual
PRODUCT INFORMATION
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements as
officially laid down at this moment.
TECHNICAL INFORMATION
- Voltage
- Frequency
- Power consumption
- Standby power consumption : < 1W
- Contents reservoir
- Colour setting
- SAP coding
OPTIONAL (accessories)
- XL watertank (10 Cups)
Commercial type number HD7982
Service code : 4222 259 20100
Published by Philips Consumer Lifestyle
11/06
: 220 - 240 V
: 50 Hz
: 1450 W
: 750 cc
: Lilac
: HD7810/31/E
Printed in the Netherlands
Coffee Maker Senseo
Water level
Sensor
L
Pump M
CONTROL
PCB
N
Push buttons
© Copyright reserved
HD7810/31/E
Temp.
Sensor
Boiler
TCO
Fuse
Fuse
Subject to modification

Advertisement

loading

Summary of Contents for Philips HD7810/31/E

  • Page 1 - SAP coding : HD7810/31/E Push buttons OPTIONAL (accessories) - XL watertank (10 Cups) Commercial type number HD7982 Service code : 4222 259 20100 Published by Philips Consumer Lifestyle Printed in the Netherlands © Copyright reserved Subject to modification 11/06...
  • Page 2 HD7810/31/E DISASSEMBLY- AND RE-ASSEMBLY ADVISE Disassembly information To remove the brew chamber lid cover handle as follows: Removing Brew chamber head handle as follows: - Place the screwdriver on the - Disassemble back cover! positions (see picture 1) and - Place the appliance such a way that you are looking at the lift the cover over the snap boiler.
  • Page 3: Repair Instruction

    HD7810/31/E REPAIR INSTRUCTION Descaling Descaling is an important element in Senseo maintenance. 7. Unplug the appliance from the mains. It should be done at least once every 3 months, up to 6 times 8. Press the 1- and 2 cup button simultaneously and plug a Year! the mains on.
  • Page 4: Parts List

    HD7810/31/E REPAIR INSTRUCTION Restoring the Boiler_empty_fl ag to production default: Some times it is needed that the boiler of the Senseo have to be emptied. This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e.g.
  • Page 5: Exploded View

    HD7810/31/E EXPLODED VIEW...
  • Page 6 HD7810/31/E EXPLODED VIEW...