ESV093C3XB
ESV123C3XB
ESV183C3XB
ESV243C3XB
EN AIR CONDITIONER
ESV093C4YB
ESV123C4YB
ESV183C4YB
ESV243C4YB
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux ESV093C3XB

  • Page 1 ESV093C3XB ESV093C4YB ESV123C3XB ESV123C4YB ESV183C3XB ESV183C4YB ESV243C3XB ESV243C4YB EN AIR CONDITIONER USER MANUAL...
  • Page 2: Table Of Contents

    12. ENVIRONMENT CONCE RNS ................26 WE’RE THINKING OF YOU Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with it decades of professional experience and innovation. Ingenious and stylish, it has been designed with you in mind. So whenever you use it, you can be safe in the knowledge that you’ll get great results every time.
  • Page 3: Safety Instructions

    ENGLISH SAFETY INSTRUCTIONS Before the installation and use of the • Installation work must be performed appliance, carefully read the supplied in accordance with the national wiring instructions. The manufacturer is not standards and the electricity suppliers responsible if an incorrect installation and service rules by authorised personnel use causes injuries and damages.
  • Page 4 4 www.electrolux.com • For safety, be sure to turn off the • Do not step on the top of the outdoor circuit breaker before performing any unit or place heavy things on it. It may maintenance or cleaning or when the cause damage or injury.
  • Page 5: Parts Name

    ENGLISH 2. PARTS NAME Indoor Unit Outdoor Unit air inlet panel filter air inlet aux. button air outlet air outlet horizontal louver If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner.
  • Page 6: Operation And Introduction Of Remote Controller

    6 www.electrolux.com 3. OPERATION AND INTRODUCTION OF REMOTE CONTROLLER 3.1 Buttons on remote controller 3.2 Introduction for icons on display screen I FEEL Set fan speed fan speed. It’s displayed only after turning it on.) Turbo mode Send signal Auto mode...
  • Page 7 ENGLISH 3.3 Introduction for buttons on remote controller NOTE For preventing cold air, after starting up heat mode, This is a general use remote controller . It could be indoor unit will delay 1~5 minutes to blow air (actual used for the air conditioner with multifunction. For the delay time depends on indoor ambient temperature).
  • Page 8 8 www.electrolux.com (some units) Press this button can select left & right swing angle. “ " may not be available. When air condi- 、 、 Fan blow angle can be selected circularly as below: tioner receives this signal, the air conditioner will blow fan automatically.
  • Page 9 ENGLISH X-FAN After starting up T-ON or T-OFF,set the constant cir- culating valid. Pressing this button in COOL or DRY mode, the After that,air conditioner will be turned on or turned off icon " " is displayed and the indoor fan will according to setting time.ON/OFF button has no effect continue operation for a while in order to dry the on setting.If you don’t need this function, please use r-...
  • Page 10 10 www.electrolux.com When selecting " " or no display with remote heating function (some units) controller, temperature indicator on indoor unit displays set temperature. Under heat mode, press "TEMP" and "CLOCK" " with remote controller, tem - When selecting "...
  • Page 11 ENGLISH 3.5 Replacement of batteries in remote controller ① ④ ② ③ Fig.1 Fig.2 Lift the cover along the direction of arrow (as shown in Fig 1 ① ). Take out the original batteries (as shown in Fig 1 ② ). Place two 7# (AAA 1.5V) dry batteries, and make sure the position of “...
  • Page 12: Clean And Maintenance

    12 www.electrolux.com 4. CLEAN AND MAINTENANCE WARNING WARNING The filter should be cleaned every three months . Turn off the air conditioner and disconnect the If there is much dust in the operation environme- power before cleaning the air conditioner to av- nt, clean frequency can be increased.
  • Page 13: Checked Items Before Maintenance

    ENGLISH 5. CHECKED ITEMS BEFORE MAINTENANCE 5.1 General phenomenon analysis Phenomenon Solution Check items Please check below ite ms before asking for Whether there’s od- Eliminate the odour Odours are maintenance. If the malfunction still can’t be our source, such as source.
  • Page 14: Installation Notice

    14 www.electrolux.com 6. INSTALLATION NOTICE WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
  • Page 15 ENGLISH 6.3 Selection of installation location 6.4 Requirements for electric connection Basic requirement Make sure the power supply matches with the requirement of air conditioner. Unstable power Installing the unit in the following places may cau- supply or incorrect wiring or malfunction. Pl- se malfunction.
  • Page 16: Installation Of Indoor Unit

    16 www.electrolux.com 7. INSTALLATION OF INDOOR UNIT Indoor outdoor Step 1: Pay attention to dust prevention and take rele vant safety mea- Choose installation location sures when opening the hole. 5-10 Recommend the installation location to the client and then confirm it with the client.
  • Page 17 ENGLISH Hex nut diameter Tightening torque (N m) drain hose 15~20 30~40 45~55 insulating pipe 70~75 Add insulating pipe in the indoor drain hose in order Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it Step 7: with tape Connect wire of indoor unit...
  • Page 18 18 www.electrolux.com drain hose connection pipe Remove the wire clip; connect the power conn- band ection wire to the wiring terminal according to the color; tighten the screw and then fix the po- wer connection wire with wire clip. indoor power cord 09K, 12K: Bind them evenly.
  • Page 19: Installation Of Outdoor Unit

    ENGLISH 8. INSTALLATION OF OUTDOOR UNIT Step 1: Fix the support of outdoor unit (select it according to the actual inst- drain vent allation situation) chassis Select installation location according to Drain hose outdoor drain joint the house structure. Step 3: Fix the support of outdoor unit on the sele- cted location with expansion screws.
  • Page 20 20 www.electrolux.com Step 6: Tighten the union nu t with torque wrench Neaten the pipes by referring to the sheet below. The pipes should be placed along the wall, bent Tightening torque(N m) Hex nut diameter reasonably and hidden possibly. Min. semidiam-...
  • Page 21: Test And Operation

    ENGLISH 9. TEST AND OPERATION 9.1 USE VACUUM PUMP CHECK AFTER INSTALLATION Remove the valve caps on the liquid valve and Check according to the following requirement gas valve and the nut of refrigerant charging vent. after finishing installation. 2. Connect the charging hose of piezometer to the Items to be checked Possible malfunction refrigerant charging vent of gas valve and then...
  • Page 22: Configuration Of Connection Pipe

    22 www.electrolux.com 10. CONFIGURATION OF CONNECTION PIPE Additional refrigerant charging amount for R32 Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe. For the unit with standard connection pipe of 5m, there is no limitation for the min length of con- nection pipe.
  • Page 23 ENGLISH B: Remove the burrs smooth surface Remove the burrs with shaper and prevent the burrs from getting into the pipe. improper expanding pipe shaper leaning damaged crack uneven surface thickness downwards the length is equal 10.2 WORKING TEMPERATURE RANGE Indoor side Outdoor side C: Put on suitable insulating pipe...
  • Page 24: Specialist's Manual

    24 www.electrolux.com 11. SPECIALIST’S MANUAL The following checks shall be applied to instal- fire extinguishing equipment shall be available to lations using flammable refrigerants: hand. Have a dry powder or CO fire extinguisher adjacent to the charging area. – the charge size is in accordance with the room size...
  • Page 25 ENGLISH Repair to intrinsically safe components – recovery equipment and cylinders conform to the appropriate standards. Do not apply any permanent inductive or capaci- d) Pump down refrigerant system, if possible. tance loads to the circuit without ensuring that this e) If a vacuum is not possible, make a manifold so will not exceed the permissible voltage and current that refrigerant can be removed from various parts...
  • Page 26: Environment Concerns

    26 www.electrolux.com In addition,a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery mac- hine, check that it is in satisfactory working order,...
  • Page 30 ESV093C3XBI ESV093C3XBE ESV123C3XBI ESV123C3XBE ESV183C3XBI ESV183C3XBE 0.72 ESV243C3XBI ESV243C3XBE ESV093C4YBI ESV093C4YBE ESV123C4YBI ESV123C4YBE ESV183C4YBI ESV183C4YBE 0.72 ESV243C4YBI ESV243C4YBE...
  • Page 53 ESV243C3XB / ESV243C4YB:...
  • Page 60 www.electrolux.com/shop...