PROFIBUS-DP Option Instruction Manual
Make sure that this instruction manual is delivered to the end user
1.
of
the PROFIBUS option for the VF-AS1/PS1.
Read this manual before installing or operating the
2.
option for the VF-AS1/PS1.
* The data given in this manual are subject to change without notice.
TOSVERT VF-AS1/PS1
PDP002Z
Notice
And keep it in a safe place for reference.
© Toshiba Schneider Inverter Corporation 2005
All rights reserved.
 
E6581279⑤
PROFIBUS

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba TOSVERT VF-AS1

  • Page 1 Read this manual before installing or operating the PROFIBUS And keep it in a safe place for reference. option for the VF-AS1/PS1. * The data given in this manual are subject to change without notice. © Toshiba Schneider Inverter Corporation 2005 All rights reserved.  ...
  • Page 2 -Toshiba inverter,drive,servo,plc E6581279⑤ Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to VF-AS1/PS1 along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals.
  • Page 3 -Toshiba inverter,drive,servo,plc E6581279⑤ ■ General Operation Danger ▼ Never disassemble, modify or repair. Doing so could result in electric shock, fire and injury. For repairs, call your sales Disassembly prohibited agency. ▼Do not attach this option to any inverter other than the VF-AS1/PS1.
  • Page 4 -Toshiba inverter,drive,servo,plc E6581279⑤ ■ Wiring Danger ▼ Shut off power when installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is Mandatory no longer lit. ▼ Electrical construction work must be done by a qualified expert.
  • Page 5 -Toshiba inverter,drive,servo,plc E6581279⑤ Introduction Thank you for purchasing a “VF-AS1/PS1 Option (PDP002Z),” for TOSVERT PROFIBUS VF-AS1/PS1 inverter. Installing this option in the VF-AS1/PS1 and using it together, data communication can be made with a host computer or other device via PROFIBUS DP (DP-V0).
  • Page 6: Table Of Contents

    -Toshiba inverter,drive,servo,plc E6581279⑤ Contents 1. OVERVIEW ..............................6 2. EXTERIOR FEATURES...........................7 2.1. PROFIBUS connector ........................8 2.2. Status indicator ..........................8 3. INSTALLING THE PDP002Z........................9 4. CONNECTING TO THE NETWORK .....................10 4.1. Installation method ........................10 4.2. Setting a station address ......................11 5. COMMUNICATIONS-RELATED PARAMETERS..................13 5.1.
  • Page 7: Overview

    -Toshiba inverter,drive,servo,plc E6581279⑤ 1. Overview The PDP002Z option allows the VF-AS1/PS1 inverter to be connected as a slave (DP-V0) into a PROFIBUS network. Up to 126 stations* can be connected to the network (* including a master. If no repeater is provided, up to 32 stations can be connected to each segment).
  • Page 8: Exterior Features

    -Toshiba inverter,drive,servo,plc E6581279⑤ 2. Exterior features The external view of this option and the name of each part are shown below. Status indicator (Refer to Section 2.2) Panel mounting tabs (Refer to Section 3)  Address switch (Refer to Section 4.2) ...
  • Page 9: Profibus Connector

    -Toshiba inverter,drive,servo,plc E6581279⑤ 2.1. PROFIBUS connector Used to connect PROFIBUS network cables. The connector is a D-Sub connector with 9 pin female and the connector pin allocation described below follows the PROFIBUS standard. Pin number Symbol Signal type Reserved  ...
  • Page 10: Installing The Pdp002Z

    -Toshiba inverter,drive,servo,plc E6581279⑤ 3. Installing the PDP002Z Install the PROFIBUS option to VF-AS1/PS1 as follows: * When this option is used together with the IO card option, attach this option to the front panel side. (1) Turn off input power of VF-AS1/PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-AS1/PS1 is no longer lit.
  • Page 11: Connecting To The Network

    -Toshiba inverter,drive,servo,plc E6581279⑤ 4. Connecting to the network 4.1. Installation method (1) Using the DIP switchon the PROFIBUS option, seta station address. (Refer to Section 4.2.) (2) Connect a PROFIBUS connector to the PDP002Z. (Refer to Section 2.1.) * If the PDP002Z is located at an end of the bus, connect a terminal resistor to it.
  • Page 12: Setting A Station Address

    -Toshiba inverter,drive,servo,plc E6581279⑤ 4.2. Setting a station address The DIP switch on the circuit board of the option is used to set a station address. Each DIP switch is ON when it is flipped to the lower position. By default, it is factory-configured to 2.
  • Page 13 -Toshiba inverter,drive,servo,plc E6581279⑤ OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF...
  • Page 14: Communications-Related Parameters

    -Toshiba inverter,drive,servo,plc E6581279⑤ 5. Communications-related parameters On the network, the VF-AS1/PS1 (including the PDP002Z) serves as a slave device. Using the parameters listed below, set the slave device on the network and its mode of operation. The GSD files used to configure the PDP002Z can be downloaded from the following web site.
  • Page 15: F851: Communication Loss Action Setting (Network Breaks)

    -Toshiba inverter,drive,servo,plc E6581279⑤ 5.1. f851: Communication Loss Action Setting (Network breaks) This parameter sets up the VF-AS1/PS1 response to a loss of communications with the PROFIBUS network. (On some occasions, the master side will need to be configured.) 0: Stop and break of connection The inverter decelerates the motor to a stop and gives the ...
  • Page 16: F830: Ppo Type Setting

    -Toshiba inverter,drive,servo,plc E6581279⑤ 5.3. f830: PPO TYPE Setting The PPO type of PDP002Z is set up by this parameter. The PROFIBUS-DP protocol uses so-called PPOs (Parameter/Process Data Objects) in cyclic communication. The figures below show the PPO types and configurations that the PDP002Z supports .
  • Page 17: Profibus Local/Remote Operation

    -Toshiba inverter,drive,servo,plc E6581279⑤ 6. PROFIBUS Local/Remote Operation The example below shows how to configure the VF-AS1/PS1 for local / remote operation. <Terminal function> F terminal .... RUN command R terminal.... PROFIBUS/Local (Terminal in this example) switching RR/S4 terminal..Operation frequency command <Wiring>...
  • Page 18: Specifications

    -Toshiba inverter,drive,servo,plc E6581279⑤ 7. Specifications Item Specifications Model number PDP002Z PROFIBUS DP-V0 PPO TYPE: 1 to 4 by No.3.072 Profile for Variable Speed Drives Technical data Connector: D-Sub 9 pin female Station address setting: DIP switch Baud rate: 9.6 kbps up to 12Mbps...