Haier HSU-28RM03/R2 - annexe 1 Operation Manual

Split type room air conditioner
Hide thumbs Also See for HSU-28RM03/R2 - annexe 1:

Advertisement

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09RM03/R2
HSU-12RM03/R2
HSU-18RM03/R2
HSU-24RM03/R2
HSU-28RM03/R2
Please read this operation manual before using the air conditioner.
No.0010561788

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-28RM03/R2 - annexe 1

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-09RM03/R2 HSU-12RM03/R2 HSU-18RM03/R2 HSU-24RM03/R2 HSU-28RM03/R2 Please read this operation manual before using the air conditioner. No.0010561788...
  • Page 2: Table Of Contents

    Contents Cautions Parts and functions Operation 6-14 Maintenance 15-17 Trouble shooting...
  • Page 3: Cautions

    Minimum: D.B / W.B C/-8 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F 3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
  • Page 4: Parts And Functions

    Lights up when Timer operation adjust up and down air flow. Lights up when unit starts. is selected. (Don't adjust it manually.) HSU-28RM03/R2 For models: HSU-24RM03/R2 Actual inlet grille may vary from the one shown in the manual according to the product purchased.
  • Page 5: Outdoor Unit

    Parts and Functions Outdoor Unit HSU-09RM03/R2 HSU-12RM03/R2 HSU-18RM03/R2 HSU-24RM03/R2 HSU-28RM03/R2 OUTLET CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE...
  • Page 6: Clock Set

    Clock set Used to reset the controller back to normal condition. When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press to set correct time.
  • Page 7 The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
  • Page 8: Operation

    When sudden power failure occurs during unit operation in power failure resume mode, or if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press...
  • Page 9 All indicators on indoor unit go out. Vertical flap closes automatically. Hints Remote controller can memorise settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reselecting is needed.(TIMER ON/OFF needs reselecting)
  • Page 10: Cool, Heat And Dry Operation

    LOW speed regardless of FAN setting. will run in mild DRY mode. Hints On cooling only unit, heating mode is not available. Remote controller can memorise each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
  • Page 11 Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7 C.
  • Page 12: Timer Operation

    TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at desired times, e.g. before you wake up in the morning, or get back from outside or after you fall asleep at night.
  • Page 13 Follow the same procedures in "Time setting for TIMER ON". (6) Time confirming for TIMER OFF After time setting, press SET button to confirm, "OFF" stops flashing Time displayed: Unit stops at X hour X min. To cancel TIMER mode...
  • Page 14: Health Operation

    The anion generator in the air conditioner can generate a lot of SLEEP HEALTH anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in LOCK RESET the room and finally clean the air in the room.
  • Page 15: Emergency Operation

    Emergency Operation: Carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a " Pi " sound starts once, which means the start of this operation. In this operation, it is not possible to change the settings of temperature and air flow speed, it is also impossible to do an operation by the timer.
  • Page 16 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. ON/OFF TEMP In COOL mode MODE One hour after SLEEP mode starts, temp. will become 1 C higher than temp.
  • Page 17: Maintenance

    Cut off power supply before cleaning unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Don't use water to wash unit casing, please use dry cloth.
  • Page 18 6.Close the Inlet Grille Close the Grille securely NOTE: Please replace the air Purifying Filter when color of the filter become same levle of sample attached in the indoor unit. Please replace the air Purifying Filter every 3-6 months as standard.
  • Page 19 Avoid time-wasteful operation Never fail to observe the followings Do not sprinkle water over Do not block the inlet or outlet. the unit. Do not pull power plug. Do not use for other purposes. Such as food preservation plant cultivation or animal breeding.
  • Page 20: Trouble Shooting

    Performance casing expanding or shrinking because of inspection temperature changes Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated. from the interior air such as the smell of furniture, cigarettes.

This manual is also suitable for:

Hsu-09rm03/r2Hsu-12rm03/r2Hsu-18rm03/r2Hsu-24rm03/r2