VG4 Modular Camera Series
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. If using UTP for video or Ethernet, connect the incoming RJ45 video connector, installed
11. Connect the outgoing alarm wires to the flying leads coming from the 4-pin Alarm
Bosch Security Systems, Inc.
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en
Route all incoming wires through one of the conduits at the bottom of the Mounting
Plate. For a mast mount, route all wires through the right-angle conduit.
Attach the water-tight plug to the other conduit.
Attach the grounding spade terminal (item 1, below) to one of the spade terminals inside
the Mounting Plate.
Figure 2.14 Mounting Plate - Inside Detail
Ref. Description
1
Grounding lug with two spade terminals
2
Earth ground lug with crimp ring terminal
3
Wire input conduit holes
Connect the incoming 24 VAC power wires to the 5-pin, 24 VAC Power In mating
connector (supplied with the Mounting Plate kit) for the Dome and for the Heater.
Attach the grounding spade from the 5-pin mating connector (item 1, Figure 2.14) to the
other spade terminal inside the mounting plate.
Attach the 5-pin Power In mating connector to the 24 VAC Power cable (cable 2)
connected to the pendant.
Remove the mating connector from the Relay Contacts cable (cable 3).
Connect the incoming relay contact wires to the mating connector. Then, reattach the
mating connector to the Relay Contacts cable.
Connect the incoming video coax cable to the BNC connector (cable 4) and slide its
plastic cover over the connector.
previously, to the UTP Video/Ethernet cable (cable 5). Refer to Section 5 Cable and Wire
Standards, page 88, for detailed wire and connection information.
Outputs cable (cable 6).